IDU set
Parameter name
item
Set outdoor temperature
for auxiliary heat source /
alternative heat source to
turn on
Set outdoor temp. when
the third-party heater
works separately
IDU
setting
Upper limit of automatic
fan speed in cooling mode
Upper limit of automatic
fan speed in heating mode
Fan
Air flow setting at fan
speed
speed 7
setting
Fan speed setting in
heating standby mode
Time to stop the fan of
IDU in heating mode
(Thermal)
Parameter range
Celsius: -5 to 20
1°C or 1°C accuracy
Fahrenheit: 23 to 68
Note: Not supported on FAPUs.
00: No limit; 01: -16°C/4°F;
00/01/02/03/
02: -14°C/7°F; 03: -12°C/10°F;
04/05/06/07/
04: -9°C/15°F; 05: -7°C/20°F;
08/09/10/11/
06: -4°C/25°F; 07: -1°C/30°F;
12/13/14/15/
08: 2°C/35°F; 09: 4°C/40°F;
16/17
10: 7°C/45°F; 11: 10°C/50°F;
12: 13°C/55°F; 13: 16°C/60°F;
14: 18°C/65°F; 15: 21°C/70°F;
16: 24°C/75°F; 17: 27°C/80°F
04/05/06/07
04: Speed 4; 05: Speed 5;
06: Speed 6; 07: Speed 7
Note: Not supported on FAPUs.
04/05/06/07
04: Speed 4; 05: Speed 5;
06: Speed 6; 07: Speed 7
Note: Not supported on FAPUs.
00/01
00: Constant speed;
01: Constant air flow
Note: Not supported on FAPUs.
00/01/14
00: Thermal; 01: Speed 1;
14: Fan speed before going to
standby mode
Note: Not supported on FAPUs.
00: Fan on; 01: 4 min;
00/01/02/03/04/
02: 8min; 03: 12min;
FF
04: 16min; FF: Main board DIP
Note: Not supported on FAPUs.
60
Remarks