Sinclair SDV4-180EA Owner's Manual

Full dc inverter system

Advertisement

Quick Links

FULL DC INVERTER SYSTEMS
OWNER'S MANUAL
SDV4-180EA
C O M M E R C I A L A I R C O N D I T I O N E R S S D V 4

Advertisement

loading
Need help?

Need help?

Do you have a question about the SDV4-180EA and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Sinclair SDV4-180EA

  • Page 1 FULL DC INVERTER SYSTEMS OWNER‘S MANUAL SDV4-180EA C O M M E R C I A L A I R C O N D I T I O N E R S S D V 4...
  • Page 2 Original instructions...
  • Page 3 Fig.1 air outlet Fix leg air inlet Refrigerant piping connection part (connection part in side) NOTE All the pictures in this manual are for explanation purpose only. They may be slightly different from the air conditioner you purchased(depend on model). The actual shape shall prevail. 16kW complying with IEC 61000-3-12.
  • Page 4: Table Of Contents

    CONTENTS PAGE It is not good for your health to expose your body to the air flow for a long time. IMPORTANT SAFETY INFORMATION............1 Do not insert fingers, rods or other objects into the air PARTS NAMES....................2 inlet or outlet. OPERATION RANGE..................3 When the fan is rotating at high speed, it will cause injury.
  • Page 5: Parts Names

    Model (18 as The capacity requirements It may cause incomplete combuston or deformation of the unit SDV4-180EA) of the revised external unit due to the heat. T3 piping temperature The quantities of the operating...
  • Page 6: Operation Range

    3. OPERATION RANGE 4.2 About power cut If power is cut during operation, stop all the operation immediately. Power comes again. The lamp on the display panel of indoor unit flashes. And then unit will auto-restart. Mishandling in operation: If mishandling happens because of lighting or mobile wireless, Table 3-1 please shut off the manual power switch, and turn on again, then push the ON/OFF button.
  • Page 7 4.5 Cooling and heating operation During operation, the fan motor in the outdoor unit may stop running under high temperature. The indoor unit of the intelligent inverter centralized air conditioner can be controlled solely, but the indoor unit in the During Fan Operation, if other Indoor Units are running on same system can not run cooling and heating at the same time.
  • Page 8: Malfunction Code Of Outdoor Unit

    MALFUNCTION CODE OF OUTDOOR UNIT Table 5-1 Malfunction or Protection Display Communication malfunction between indoor/outdoor units T3&T4 temperature sensor malfunction Power voltage protection Fan Protection Compressor discharge temperature sensor malfunction EEPROM malfunction A fan in the Aregion run for more than 5 minutes in Heat mode 2 times of E6 protection in 10 minutes Communication malfunction between IR341/main board Hi-pressure protection...
  • Page 9: Following Symptoms Are Not Air Conditioner Troubles

    6. FOLLOWING SYMPTOMS ARE NOT AIR Symptom 4.2: Indoor unit, outdoor unit CONDITIONER TROUBLES A continuous low hissing sound is heard when the system is in operation. Symptom 1: The system does not operate This is the sound of refrigerant gas flowing through both indoor and outdoor units.
  • Page 10 Table 7-1 Symptoms Causes Solution Power failure. Wait for the comeback of power. Power switch is off. Switch on the power. Fuse of power switch may have burned. ReplLocation: Unit does not start Unit does not start Batteries of remote controller exhausted Replace the batterises or check the or other problem of controller.
  • Page 11 7.2 Troubles and causes of remote controller Before asking for serving or repairing , check the following points. (see in Table 7-2) Table 7-2 Symptoms Causes Solution Check whether the MODE When the automatic mode is indicated on the display is selected, the air conditioner will "AUTO"...
  • Page 12 Waste Acts of respective country, in the Czech Republic in Act no. 185/2001 Coll., in the wording of later regulations. In case of incorrect disposal of this waste, a fine can be imposed according to national regulations. Manufacturer: Sinclair Corporation Ltd. 1-4 Argyll Street London W1F 7LD United Kingdom Supplier and technical support: Nepa, spol.s.r.o.