8.3 Wired controller Configuration
Menu
Submenu
Set main and sec. wired controller
0.5 degree Temp. Adjustment or not
Set temp. range/cool and
heat
Rem control rcpt of wired controller
Wired controller Auto restore
Perf. degradation
Filter blocked rate
Filter clean reminder
Filter reset
wired controller light
Separ one-to-more ctrl/swing
After hours
Third-level menu
main/second
Set temp. format: 0.5/1
Set upper and lower
temp. limits in
cooling/heating mode
Enable/Disable
Enable/Disable
On/Off
On/Off
00: No reminder to filter
01:500h,02:1000h,
03:2500h,04:5000h
On/Off
On/Off
30 min, 60 min, 90 min,
120 min, 180 min,
240 min, invalid
58
Default
Remarks
Master WDC
0.5
Common
The room
temperature range
SDV6 IDUs:
that can be set with
16°C–30°C
a wired controller is
Common
13–30°C. The
SDV5 IDUs:
FAPU treats the
17°C–30°C
temperature below
SDV6 FAPU:
16°C as 16°C, and
13°C–30°C
the wired controller
SDV5 FAPU:
displays the actual
13°C–30°C
set operating
temperature of the
FAPU.
Enable
Enable
Off
only SDV6 IDU
Off
only SDV6 IDU
500h
On
Off
only SDV6 IDU