Sinclair SDV4 series User Manual

Outdoor non-combinable units (25,0-45,0kw)
Hide thumbs Also See for SDV4 series:

Advertisement

USER'S MANUAL
SDV4
OUTDOOR NON-COMBINABLE UNITS
(25,0-45,0kW)

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SDV4 series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Sinclair SDV4 series

  • Page 1 USER'S MANUAL SDV4 OUTDOOR NON-COMBINABLE UNITS (25,0-45,0kW)
  • Page 2 Original instructions Thank you very much for purchasing our air conditioner, Before using your air conditioner , please read this manual carefully and keep it for future reference.
  • Page 3: Table Of Contents

    Never inspect or service the unit by yourself. CONTENTS PAGE Ask a qualified service person to perform this work. IMPORTANT SAFETY INFORMATION............. Do not dispose this product as unsorted municipal PARTS NAMES..................waste. Collection of such waste separately for special OPERATION AND PERFORMANCE............
  • Page 4: Parts Names

    Do not place appliances which produce open fire in places exposed to the air flow from the unit or under the Cooling and heating operation of Sinclair inverter central A/C indoor unit. It may cause incomplete combuston or deformation of the ●...
  • Page 5: Troubles And Causes

    3. When the Priority Mode has been set, the first indoor unit will Protection Device work in Heating Mode that is Heating Priority, please refer to the This protection device will stop the unit automatically in case ITEM 1 for the control logic. If the first indoor unit is work in the air conditioner is on forced running mode.
  • Page 6 Please read the following illustration(before apply for servicing) Table.4-1 Troubles Causes Outdoor unit FAN function stop automatically to defrost. It is White mist or water the start and stop sound of the solenoid valve The sound of “hiss” At the beginning and the end of the running process, sounds like water flow in valve occurs, which will be amplified in 3~15 minutes, this is caused by dehumidifying process of refrigerant...
  • Page 7: Malfunction

    P7:Fixed frequency 1 current protection; P8:Fixed frequency 2 current protection 2. For the models with only one inverter compressor, P7:Reserve ; P8:Reserve If the problem still existing, please contact the sales distributor or Sinclair service center, tell us your model No. and the detail of the error. owner's manual...
  • Page 8: Constraint Cooling And Query

    6. CONSTRAINT COOLING AND QUERY MAIN BOARD (OUTDOOR UNIT) Query button Constraint Cooling Once pressing the constraint cooling button(see the chart on the Constraint cooling button right), all the indoor unit will be on forced cooling mode and the wind speed is HIGH. COOL CHECK Fig.6-1...
  • Page 9: After-Sales Service

    6) Indoor unit qty.: The indoor unit which communicate with outdoor unit normally. 7. AFTERSALE SERVICE If the air conditioner was operate abnormally, please plug off the power supply firstly, and contact with Sinclair After-sales Center or Special Distributor. For detail please refer to the attached accessory Consumer Service Instruction.
  • Page 10 Waste Acts of respective country, in the Czech Republic in Act no. 185/2001 Coll., in the wording of later regulations. In case of incorrect disposal of this waste, a fine can be imposed according to national regulations. Manufacturer: Sinclair Corporation Ltd. 1-4 Argyll Street London W1F 7LD United Kingdom Supplier and technical support: Nepa, spol.s.r.o.

Table of Contents