Download Print this page
Sinclair SDV4 F Owner's Manual

Sinclair SDV4 F Owner's Manual

Indoor units with dc fan motor

Advertisement

Quick Links

Библиотека СОК 
FULL DC INVERTER SYSTEMS
OWNER'S MANUAL
INDOOR UNITS WITH DC FAN MOTOR
C O M M E R C I A L A I R C O N D I T I O N E R S S D V 4

Advertisement

loading
Need help?

Need help?

Do you have a question about the SDV4 F and is the answer not in the manual?

Questions and answers

Summary of Contents for Sinclair SDV4 F

  • Page 1 Библиотека СОК  FULL DC INVERTER SYSTEMS OWNER‘S MANUAL INDOOR UNITS WITH DC FAN MOTOR C O M M E R C I A L A I R C O N D I T I O N E R S S D V 4...
  • Page 2 Original instructions owner’s manual...
  • Page 3: Table Of Contents

    Never replace a fuse with that of wrong rated current or CONTENTS PAGE other wires when a fuse blows out. Use of wire or copper wire may cause the unit to break down or cause a fire. IMPORTANT SAFETY INFORMATION............1 PARTS NAMES....................
  • Page 4: Parts Names

    2. PARTS NAMES In order to avoid electric shock or fire, make sure that an earth leak detector is installed. ■ Four-way cassette type Be sure the air conditioner is grounded. In order to avoid electric shock, make sure that the unit is Air Out Louver (Adjustable) grounded and that the earth wire is not connected to gas or Two-direction or Three-direction Air...
  • Page 5: Air Conditioner Operations And Performance

    ■ High static pressure duct type ■ Console type Installation part Heat Exchanger Air flow louver (Exchange cool air into warm air) Air Outlet Display panel (at air outlet) (Outlet room air) Air inlet (with air filter in it) Air flow louver Drain pipe (at air outlet) Air Intake...
  • Page 6: Adjusting Air Flow Direction

    4. ADJUSTING AIR FLOW DIRECTION. Please note the following correct operation for saving energy and achieve the quick and comfortable cooling/heating effects. Because cold air flow down and hot air flow up,to improve the the cooling and heating effect, please adjust air flow louver ●...
  • Page 7 ● Manual swing ● When heating Adjust the louver to achieve the better cooling/ heating Adjust the louver downwards (vertically). effects when cooling/heating. ● When cooling Adjust the louver horizontally. Fig.4-12 ■ Console type ● When heating ■ Adjust the air direction up and down Adjust the louver downwards (vertically).
  • Page 8: Maintenance

    ■ Adjust the air direction left and rught CAUTION Hold the knob and move the louver.You will find a knob on the left-side and the right-side blades. For switching the Auto/Manual mode of the lower air outlet, one should plug off and restart the unit for mode renewing. 5.
  • Page 9 Hold the tabs of the frame,and remove the claws in 4 places. (The especial function filter can be renewed by washing it with water once every 6 months.We recommend replacing it once every 3 years.) Fig.5-1 especial function filter Fig.5-8 Maintenance after a long stop period (eg.
  • Page 10: Following Symptoms Are Not Air Conditioner Troubles

    6. FOLLOWING SYMPTOMS ARE NOT AIR A hissing sound which is heard at the start or immediately after stopping operation or defrost operation. CONDITIONER TROUBLES This is the noise of refrigerant caused by flow stop or flow change. Symptom 1: The system does not operate Symptom 4.3: Outdoor unit The air conditioner does not start immediately after the ON/OFF When the tone of operating noise changes.
  • Page 11: Troubleshooting

    7. TROUBLE SHOOTING Troubles and causes of air conditioner If one of the following malfunctions occur, stop operation, shut off the power, and contact with your dealer. Remote controller receives malfunction or the button does not work well. A safety device such as a fuse, a breaker frequently actuates. Obstacles and water enter the unit.
  • Page 12 Troubles and causes of remote controller Before asking for serving or repairing, check the following points.(See in Table 7-2) Table 7-2 Symptoms Causes Solution Check whether the MODE When the automatic mode is indicated on the display is selected, the air conditioner will "AUTO"...
  • Page 13 Fault information and code Fault information is only appicable for the indoor units with panel,and only the panel with digit displays will shows the fault code,otherwise just four LED lamps. The fault indication of LED and digit displays see the following form. The Fault Indication Of LED The Fault Indication Of Digit Displays Table.7-3...
  • Page 14 The value GWP: 2088 GWP = Global Warming Potential In case of quality problem or other please contact your local supplier or authorized service center. Emergency number: 112 PRODUCER SINCLAIR CORPORATION Ltd. 1-4 Argyll St. LONDON W1F 7LD United Kingdom www.sinclair-world.com...

This manual is also suitable for:

Sdv4