Electrical Connection; Electrical Connection Table - Bertazzoni MAS486GDFMXV Installation, User And Maintenance Manual

Freestanding dual fuel ranges, gas worktop, electric manual clean oven
Table of Contents

Advertisement

ELECTRICAL CONNECTION

WARNING
ELECTRICAL
Disconnect electrical power at the circuit
breaker box or fuse box before installing
the appliance.
Provide
appropriate
appliance.
Use copper conductors only.
Failure to follow these instructions could
result in serious injury or death.
This unit is manufactured for a polarized, grounded 120
volt/60 Hz, 16 amp system.
Electric power consumption is about 300 W for 30" and 36",
1200W for 48".
The minimum of 102 VAC is required for proper operation
of gas ignition systems.
The circuit must be grounded and properly polarized.
The unit is equipped with a SJT power cord and a NEMA 5-
15P plug. In case of replacement, the power cord shall be
replaced with one of the same type, size and length.
WARNING
Electrical grounding
This appliance is equipped with a four-
prong plug for your protection against
shock hazard and should be plugged
directly into a properly grounded socket. Do
not cut or remove the grounding prong from
this plug.
TYPE
VOLTAGE
48 DFM
120/208V
120/240V
16
SHOCK
HAZARD
ground
for
the
CIRCUIT
ELECTRICAL
RATING
5400W 30A
6700W 37A
CAUTION
Label all wires prior to disconnecting when
servicing controls. Wiring errors can cause
improper and dangerous operation.
Verify proper operation after servicing.
The appliance shall be connected to a single phase electric
line rated at 120/208Vac or 120/240Vac and 60Hz
frequency.
Install a suitable electric power supply receptacle
connection type NEMA 14-50R able to support a load of at
least an ampacity as per indication in following table.
Install a suitable electric power supply receptacle
connection type NEMA 14-50R able to support a load of at
least 30 A (per line) according to local code requirements.
For four or three wires power supply connection system
see diagram below.
Fig. 7 FOUR-WIRE CONN.RECEPTACLE NEMA 14-50R
Check your local code for which of the options below
should be used in grounding the receptacle power supply
connections.

ELECTRICAL CONNECTION TABLE

FMC SIZE
SUPPLY
L1 (black)
L2 (red)
40A
1"
40A
CONNECTORS WIRES SIZE
N (white)
G (green)
12
10