1. Do not place Propane supply tank(s) in-
side any structure. Propane supply tank(s)
must be placed outdoors.
2. This heater shall not be installed in a
bedroom or bathroom.
3. This heater needs fresh air ventilation to
run properly. This heater has an Oxygen
Depletion Sensing (ODS) safety shutoff
system. The ODS shuts down the heater
if not enough fresh air is available. See
Air for Combustion and Ventilation, pages
7 and 8. If heater keeps shutting off, see
Troubleshooting, pages 20 through 22.
4. Keep all air openings in front and bottom
of heater clear and free of debris. This will
ensure enough air for proper combustion.
5. If heater shuts off, do not relight until you
have provided fresh, outside air. If heater
keeps shutting off, have it serviced.
6. Do not run heater:
• Where flammable liquids or vapors are
used or stored.
• Under dusty conditions.
Only a qualified agency should install and
replace gas piping, gas utilization equipment
or accessories. Repair and equipment ser-
vicing should allways be done by a qualified
agency.. The term "qualified agency" means
any individual, firm, corporation, or company
that either in person or through a representa-
tive is engaged in and is responsible for:
4

QUALIFIED INSTALLING AGENCY

www.usaprocom.com
SAFETY
7. Before using furniture polish, wax, carpet
cleaner, or similar products, turn heater off.
If heated, the vapors from these products
may create a white powder residue within
burner box or on adjacent walls or furniture.
8. Always run heater with control knob at
LOW or HIGH locked positions. Never set
control knob between locked positions.
Poor combustion and higher levels of
carbon monoxide may result.
9. Do not use heater if any part has been
under water. Immediately call a qualified
service technician to inspect the room
heater and to replace any part of the
control system and any gas control which
has been under water.
10. Turn off and unplug heater and let cool
before servicing. Only a qualified service
person should service and repair heater.
11. Operating heater above elevations of
4,500 feet could cause pilot outage.
12. To prevent performance problems, do not
use propane fuel tank of less than 100 lbs.
capacity.
a) Installing, testing, or replacing gas piping
or
b) Connecting, installing, testing, repairing,
or servicing equipment; that is experienced
in such work; that is familiar with all precau-
tions required; and that has complied with
all the requirement of the authority having
jurisdiction.