WARNING: Never install the
heater
• in a bedroom or bathroom
• in a recreational vehicle
• where curtains, furniture,
clothing, or other flammable
objects are less than 36" from
the front, top, or sides of the
heater
• in high traffic areas
• in windy or drafty areas
IMPORTANT: Vent-free heaters add moisture
to the air. Although this is beneficial, installing
heater in rooms without enough ventilation air
may cause mildew to form too much moisture.
See Air for Combustion and Ventilation, pages
7 and 8.
CHECK GAS TYPE
Be sure your gas supply is right for your heat-
er. Otherwise, call dealer where you bought
the heater for proper type heater.
CLEARANCES TO
COMBUSTIBLES
Carefully follow the instructions below. This
heater is a freestanding unit designed to be
mounted on a wall or set on a base.
WARNING: Maintain the
minimum clearances shown in
Figure 4. If you can, provide
greater clearances from floor,
ceiling, and joining wall.
CEILING
8"
Minimum
From
Sides of
Heater
Left
Side
2" Minimum to Top Surface of Carpeting,
Tile or Other Combustible Material
FLOOR
Figure 4 - Mounting Clearances as
Viewed From Front of Heater
200045-02A

INSTALLATION

ates warm air currents. These
currents move heat to wall sur-
faces next to heater. Installing
heater next to vinyl or cloth wall
coverings or operating heater
where impurities (such as to-
bacco smoke, aromatic candles,
cleaning fluids, oil or kerosene
lamps, etc.) in the air exist, may
cause walls to discolor.
This heater is designed to be mounted on a
wall. You can locate heater on the floor, away
from a wall. An optional floor mounting stand
is needed. See Installation of Base Stand,
page 12.
For convenience and efficiency, install heater:
1. Where there is easy access for operation,
inspection, and service.
2. In the coldest part of room.
An optional fan kit is available from your dealer
See Accessories, page 27. If planning to use
fan, locate heater near an electrical outlet.
RELOCATING THERMOSTAT
SENSING BULB ( OPTIONAL )
1. Pull out the sensing bulb from the two clips
located in the shipping position according
to the direction as shown by the arrow.
There is no need to take out the two bulb
clips.
36"
Minimum
Right
Side
Figure 5 - Moving Thermostat Sensing
www.usaprocom.com
CAUTION: This heater cre-
LOCATING HEATER
Hole for Installing Clip
Bulb
Pull
Out
9