Procom ML060HBA Owner's Operation And Installation Manual

Procom ML060HBA Owner's Operation And Installation Manual

Blue flame vent-free propane/lp gas space heater

Advertisement

OWNER ' S OPERATION AND INSTALLATION MANUAL
ML060HBA ML100HBA ML100TBA

Table of Contents

Important Safety Information.................................2
Product Features.....................................................3
Proper Ventilation & Fresh Air...............................4
Installation................................................................6
Operating Your Heater...........................................10
Cleaning & Maintenance.......................................13
Trouble Shooting...................................................14
Specifications..........................................................17
Parts List.................................................................19
WARNI NG: If the information in this
manual is not followed exactly, a f i r e o r
e x p l o s i o n
m a y
damage, personal injury, or loss of life.
WARNING: This is an unvented gas-fired
heater. It uses air (oxygen) f r o m t h e r o o m
i n
w h i c h
i t
i s installed. Provisions for
adequate combustion and ventilation air must
b e p r o v i d e d . R e f e r t o A i r F o r Combus-
tion and Ventilation section on page 4 of this
CONTINENTAL APPLIANCE INC/U.S. OFFICE
5 Musick
Irvine
CA 92618
Nanjing PRO-COM Electric Appliance Co.,Ltd.
#6 Chuangye Road,High New Tech.Zone,
Great Bridge Road North,Nanjing,210061,
China.
TOLL FREE NUMBER: 1-877-886-5989
r e s u l t causing property
4600 Highlands Parkway S.E
Suite # D/E
Smyrna, GA 30080
Do not store, or use gasoline or other flammable
vapors and liquids in the vicinity of this or any
other appliance.
WHAT TO DO IF YOU SMELL GAS
l Do not try to light any appliance.
l Do not touch any electrical switch; do not
use any phone in your building.
l Immediately call your gas supplier from a
neighbor's phone. Follow the gas supplier's
instructions.
l
If you cannot reach your gas supplier, call
the fire department.
Installation and service must be performed by a
qualified installer, service agency or gas
supplier.
WA R N I N G :
adjustment, alteration, service or mainte-
nance can cause injury or property damage.
Refer to this manual for correct installation and
operational procedures. For assistance or
additional information consult a qualified
installer, service agency, or gas supplier.
This appliance may be installed in an aftermar-
ket*
permanently
(mobile) home, where not prohibited by local
codes.
This appliance is only for use with the type of
gas indicated on the rating plate. This
appliance is not convertible for use with other
gases.
*Aftermarket: Completion of sale, not for purpose of
resale, from the manufacturer.
WATER VAPOR: A BY-PRODUCT OF UNVENTED
ROOM HEATERS
Water vapor is a by-product of gas combustion. An
unvented room heater produces approximately one
(1) ounce (30ml) of water for every 1,000 BTU's
(.3KW's) of gas input per hour. Refer to page 3.
.
Installer: Please leave these instructions with the
consumer.
Consumer: Please retain these instructions for
future use.
BLUE FLAME VENT-FREE
PROPANE/LP GAS
SPACE HEATER
I m p r o p e r
i n s t a l l a t i o n ,
located, manufactured
PR-ML062-16-0803

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ML060HBA and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Procom ML060HBA

  • Page 1: Table Of Contents

    Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions. If you cannot reach your gas supplier, call ML060HBA ML100HBA ML100TBA the fire department. Installation and service must be performed by a Table of Contents qualified installer, service agency or gas supplier.
  • Page 2: Important Safety Information

    WARNING assemble, operate, or service 9. Do not use heater if any part Modeles ML060HBA, ML100HBA, this heater. Improper has been under water. ML100TBA are equipped for propane this heater can cause serious gas.
  • Page 3: Product Features

    PRODUCT FEATURES Figure1-Vent-Free Propane/LP Gas Heater SAFETY DEVICE LOCAL CODES A standard requirement for all vent-free room Install and use heater with care. Follow all local heaters. This heater has a pilot with an Oxygen codes. In the absence of local codes, use the Depletion Sensor(ODS) safety shutoff system.
  • Page 4: Proper Ventilation & Fresh Air

    Confined and Unusually Tight Construction FRESH AIR FOR The air that leaks around doors and Unconfined Space COMBUSTION AND windows may provide enough fresh The National Fuel Gas Code VENTILATION air for combustion and ventilation. ANS Z223.1 defines a confined However, in buildings of unusually space as a space whose volume WARNING: This heater...
  • Page 5: Air For Combustion And Ventilation

    3. Add the Btu/Hr of all fuel burning appliances in the space. Vent-free heater Btu/Hr Gas water heater* Btu/Hr Example: Gas furnace Btu/Hr Gas water heater 44,000 Btu/Hr Vented gas heater Btu/Hr Vent free heater 10,000 Btu/Hr Gas Fireplace logs Btu/Hr Total 54,000...
  • Page 6: Installation

    ML100HBA and ML100TBA, only Propane/LP heat. Use this heater along with sealant (resistant to ML060HBA is allowed in bathroom. Check local codes.) your primary heating system. Do gas) in a recreational vehicle. not install this heater as your...
  • Page 7 INSTALLATION FASTENING HEATER TO WALL Attaching to Wall Stud: This method WARNING: Maintain the Mounting Bracket provides the strongest hold. Insert minimum clearances shown The mounting bracket is located mounting screws through mounting F i g u r e 4 . y o u c a n , back panel of heater (see bracket and into wall studs.
  • Page 8 INSTALLATION Attaching Mounting Bracket To IMPORTANT: Do not Wall hammer key! For thick walls Note: Wall anchors, mounting " (over 1/2 thick) or solid walls, screws, and spacers are in do not pop open wings. hardware package. The hardware package is provided with heater. Attaching to Wall Stud Method Figure 12 - Installing Bottom For attaching mounting bracket to...
  • Page 9 INSTALLATION CONNECTING TO GAS SUPPLY WARNING: A qualified service person must connect heater to gas supply. Follow all local codes. WARNING: This appliance " requires a 3/8 NPT (National Pipe T h r e a d ) i n l e t c o n n e c t i o n to the pressure regulator.
  • Page 10: Operating Your Heater

    INSTALLATION OPERATING YOUR HEATER CHECKING GAS Pressure Testing Heater Gas NON-THERMOSTAT MODEL CONNECTIONS Connections 1. Open equipment shutoff valve FOR YOUR SAFETY Test all gas piping WARNING: (see Figure 15). READ BEFORE LIGHTING and connections for leaks after Open propane/LP supply tank installing or servicing.
  • Page 11: Operating Your Heater

    Turn control knob clockwise gas, including near the floor. Figure 17 -1- Control Knob In to the PILOT/IGN position. smell gas, STOP! The OFF Position (ML060HBA) " " Follow safety information on the side of the heater. If you do not smell MANUAL LIGHTING gas, go to the next step.
  • Page 12 OPERATING YOUR HEATER THERMOSTAT MODEL Wait five(5) minutes to clear CAUTION: Do not try to out any gas. Then smell for gas, adjust heating levels by using the including near the floor. If you FOR YOUR SAFETY equipment shutoff valve. “...
  • Page 13: Cleaning & Maintenance

    OPERATING HEATER BURNER FLAME PATTERN ODS/PILOT AND BURNER Continued Figure 23 shows a correct burner Use a vacuum cleaner, pres- flame pattern. Figure 24 shows an MANUAL LIGHTING surized air, or a small, soft incorrect burner flame pattern. If bristled brush to clean. PROCEDURE pilot flame pattern is incorrect, as Remove lower front panel (see...
  • Page 14: Troubleshooting

    TROUBLESHOOTING Note : troubleshooting WARNING: Only a qualified CAUTION: Never use a wire, items are listed in order of needle, or similar object to clean service person should service and operation. ODS/pilot. This can damage repair heater. ODS/pilot unit. OBSERVED PROBLEM POSSIBLE CAUSE REMEDY When ignitor button is pressed in,...
  • Page 15 TROUBLESHOOTING Continued POSSIBLE CAUSE REMEDY OBSERVED PROBLEM 1. Burner orifice is clogged. 1. Clean burner orifice (see Cleaning Burner(s ) d o e s n o t l i g h t a f t e r and Maintenance Page 13) or ODS/pilot is lit.
  • Page 16 TROUBLESHOOTING Continued WARNING: If you smell gas Shut off gas supply. Do not try to light any appliance. Do not touch any electrical switch; do not use any phone in your building. Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.
  • Page 17: Specifications

    If so, contact your local propane/LP Contact authorized dealers of this FLOOR MOUNTING STAND gas supplier. product. If they can’t supply original Models ML060HBA,ML100HBA, ACCESSORIES replacement part(s), contact PRO- ML100TBA Purchase these heater accesso- COM through the phone number 1- For locating heater on the floor away ries from your local dealer.
  • Page 18 ILLUSTRATED PARTS BREAKDOWN ML060HBA...
  • Page 19: Parts List

    PARTS LIST This list contains replaceable parts for your heater. When ordering replacement parts, follow the instructions listed under Replacement Parts on page17 of this ML060HBA manual. QTY. PART NO. DESCRIPTION MB10008 Cabinet Assembly MB09003 Lower Front Panel Assembly MB11005...
  • Page 20: Manual

    ILLUSTRATED PARTS BREAKDOWN ML100HBA...
  • Page 21: Manual

    PARTS LIST This list contains replaceable parts for your heater. When ordering replace- ment parts, follow the instructions listed under Replacement Parts on page17 ML100HBA of this manual. QTY. PART NO. DESCRIPTION MB10008 Cabinet Assembly MB09003 Lower Front Panel Assembly MB11005 Reflector Unit ML086-03...
  • Page 22: Manual

    ILLUSTRATED PARTS BREAKDOWN ML100TBA...
  • Page 23: Manual

    PARTS LIST This list contains replaceable parts for your heater. When ordering replace- ML100TBA ment parts, follow the instructions listed under Replacement Parts on page17 of this manual. DESCRIPTION PART NO. Cabinet Assembly MB10007 Lower Front Panel Assembly MB09003 MB11005 Reflector Unit ML086-03 Glass...

This manual is also suitable for:

Ml100hbaMl100tba

Table of Contents