Procom MN180TPA-B Owner's Operation And Installation Manual page 17

Vent-free gas space heater
Table of Contents

Advertisement

Thermocouple
Ignitor Electrode
Pilot
Burner
Figure 19 - Pilot
The thermostatic control used on this model
differs from standard thermostats. You set
standard thermostats to a specific tempera-
ture such as 72° F. The control of this heater
establishes a "comfort level". In order for the
thermostat to operate effectively, the heater
should be the main source of heat in the
room. Follow the instructions for lighting the
heater on page 16. When the room reaches
the desired comfort level, rotate the control
knob clockwise slowly until the main burner
turns off and the pilot remains on (this position
on the knob will change depending on room
temperature).
Turn the knob counter-clockwise slowly until
the main burner reignites. Note the position
of the control knob by the numbers printed
on the knob. Leave the knob in this position.
Turn control knob clockwise
OFF position.
1. Remove lower front panel.
2. Follow steps 1 through 5 under Lighting
Instructions, page 16.
3. With control knob pressed in, strike match.
Hold match to pilot until pilot lights.
4. Keep control knob pressed in for 30 sec-
onds after lighting pilot. After 30 seconds,
release control knob. Follow step 8 under
Lighting Instructions, page 16.
5. Replace lower front panel.
200045-02A
OPERATION
Control Knob
THERMOSTAT CONTROL OPERATION
TO TURN OFF GAS TO APPLIANCE
Shutting Off Heater
MANUAL LIGHTING PROCEDURE
www.usaprocom.com
Figure 20- Burner Patterns
As the room temperature increases, the main
burner will turn off and the pilot will remain
on. When the room temperature cools, the
heater's main burner will come back on. If left
at this set point the thermostat will turn the
main burner on or off as needed to maintain
the room temperature at the desired comfort
level.
Note: The thermostat sensing bulb reacts
to the temperature depending on house's
construction.
CAUTION: Do not try to ad-
just heating levels by using the
equipment shutoff valve.
Shutting Off Burner Only (pilot stays lit)
to the
Turn control knob clockwise
PILOT position.
Thermocouple
Figure 21 - Pilot Assembly
LOW-HIGH
OFF
Ignitor Electrode
Pilot Burner
to the
17

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ml150tpa-bMn300tpa-bMl250tpa-b