Product Features; Local Codes; Qualified Installing Agency - Procom PCNSDS24RT Manual

Vent-free gas log heater
Table of Contents

Advertisement

service technician to inspect the room
heater and to replace any part of the
control system and any gas control which
has been under water.
11. Turn off and let cool before servicing. Only
a qualified service person should service
and repair heater.
12. Operating heater above elevations of
4,500 feet could cause pilot outage.
This log set has been tested and approved to ANSI Z21.11.2 standard for Unvented Heaters
and can be operated with the flue damper closed. State and local codes in some areas prohibit
the use of vent-free heaters.
SAFETY PILOT
This heater has a pilot with an Oxygen Deple-
tion Sensing (ODS) safety shutoff system. The
ODS/pilot shuts off the heater if there is not
enough fresh air.
PIEZO IGNITION SYSTEM
This heater is equipped with an electronic
piezo control system. This system requires
AAA batteries (provided).
Install and use heater with care. Follow all
local codes. In the absence of local codes,
use the latest edition of The National Fuel
Gas Code, ANSI Z223.1/NFPA 54*.
*Available from:
American National Standards Institute, Inc.
1430 Broadway
New York, NY 10018
National Fire Protection Association, Inc.
1 Batterymarch Park
Quincy, MA 02269-9101
Only a qualified agency should install and
replace gas piping, gas utilization equipment
or accessories, and repair and equipment ser-
vicing. The term "qualified agency" means any
individual, firm, corporation, or company that
either in person or through a representative
is engaged in and is responsible for:
a) Installing, testing, or replacing gas piping
or
b) Connecting, installing, testing, repairing, or
200240-01C

PRODUCT FEATURES

LOCAL CODES

QUALIFIED INSTALLING AGENCY

www.usaprocom.com
SAFETY
13. Do not use this heater if any log is broken.
Do not operate heater if a log is chipped
(dime-size or larger).
14. To prevent performance problems, do not
use propane fuel tank of less than 100 lbs.
capacity.
15. Solid fuels should not be burned in
fireplace in which a vent-free log set is
installed. Do not use this heater to cook
food or burn paper or other objects.
2 GAS OPTIONS AVAILABLE
Your heater is equipped to operate on either
propane or natural gas. The heater is shipped
from the factory ready for connecting to pro-
pane. The heater can easily be changed to
natural gas by having your qualified installer
follow the instructions on page 12 and the
markings on the heater.
State of Massachusetts: The installation
must be made by a licensed plumber or gas
fitter in the Commonwealth of Massachusetts.
Sellers of unvented propane or natural
gas-fired supplemental room heaters shall
provide to each purchaser a copy of 527
CMR 30 upon sale of the unit.
In the State of Massachusetts the gas
cock must be a T-handle type. The State
of Massachusetts requires that a flexible
appliance connector cannot exceed three
feet in length.
servicing equipment; that is experienced in
such work; that is familiar with all precautions
required; and that has complied with all the
requirement of the authority having jurisdiction.
In areas that prohibit the use of vent-free
heaters, the log set has been tested and
approved to the ANSI Z21.60 standard for
Vented Decorative Logs. When used as a
vented log set refer to additional instructions
on page 11.
5

Advertisement

Table of Contents
loading
Need help?

Need help?