5.7.2

Readout to dlms

dlms specification
Objective
© Landis+Gyr AG
The energy supply company can select by parameterisation between a
standard identification or its own identification. The standard identification
has the following structure:
/LGZ...
/LGZ 4...
/LGZ4 \2...
/LGZ4\2 ZMD410...
/LGZ4\2ZMD410 41...
/LGZ4\2ZMD41041 00...
/LGZ4\2ZMD4104100 .B31
Stored values
e.g. 1.6.1*04
e.g. 1.6.1&04
Identification by the energy supply company itself uses an identification
number. ID1.1 (designation of ownership by the energy supply company),
ID1.2 (any desired number) or ID2.1 (serial number) are available. The
identification is comprised as follows in this case:
/LGZ...
/LGZ 4...
/LGZ4 \2...
/LGZ4\2 \B31...
/LGZ4\2\B31 12345678
While the readout according to IEC 62056-21 uses a protocol determined in
advance, readout to dlms enables the power supply company to configure
the values to be read out individually. The company therefore has system-
atic access to specific values without being influenced by other values that
are not required.
Various meter manufacturers – including Landis+Gyr – together with
related organisations, have compiled the language specification dlms
(Device Language Message Specification) and undertaken to use this in
their equipment (meters, tariff units, systems, etc.).
The objective of dlms is to use a common language for data exchange in
the energy measurement and other sectors. In addition to end units such
as meters, tariff units, etc. dlms also concerns the interfaces, transmission
channels and system software.
D000030110 d – E650 Series 3 (ZMD400AT/CT, ZFD400AT/CT) – User Manual
Manufacturer
(Landis+Gyr)
Baud rate 4 = 4800 Baud
Extended communication possibility
2 = DLMS-compatible meter
Meter
Type of measuring unit
Basic version tariff section
Additional functions
(auxiliary power supply)
Firmware version
The hyphen following the identification
number and the rate (1.6.1) denotes the
type of resetting:
*04
Resetting made internally or
remote controlled
&04
Resetting performed manually or
with reset key R
Manufacturer
(Landis+Gyr)
Baud rate 4 = 4800 Baud
Extended communication possibility
2 = DLMS-compatible meter
Meter
Firmware version
Identification number specified
by parameterisation (maximum 8
characters)
Operation