enphase IQ7+ Installation And Operation Manual page 27

Microinverters
Table of Contents

Advertisement

Maximum output current
Nominal frequency
Minimum/maximum frequency
Maximum units per single/multi-phase
20 A circuit
Protective class (all ports)
Total harmonic distortion
Power factor setting
Power factor range
Inverter maximum efficiency
IS/IEC 61683 efficiency
Inverter topology
Night-time power loss
Ambient air temperature range
Relative humidity range
Overvoltage class AC port
Number of input DC connectors (pairs)
per single MPP-tracker
AC connector type
DC connector type
Dimensions (HxWxD)
Weight (with mounting plate)
Cooling
27
IQ7+ and IQ7A Installation and Operation Manual - India
IQ7PLUS-72-2-INT Microinverter parameters
l
acmax
f
nom
f
/ f
min
max
16 A/I
acmax
cosphi
η
max
η
IS
Mechanical data
-40°C to 65°C
4% to 100% (condensing)
III
1
IQ Cabling (refer to separate datasheet for cable and
accessories)
Staubli MC4 (using Q-DCC-2 adapter)
212 mm (8.3") x 175 mm (6.9") x 30.2 mm (1.2") (without
mounting brackets)
1.08 kg (2.38 lbs)
Natural convection – no fans
© 2023 Enphase Energy Inc. All rights reserved.
A
1.28
Hz
50
Hz
45/55
12 (L+N)/36 (3L+N)
For IQ Cable with 2.5 mm
stranded conductors and
using a 1.25 safety factor, 16
A per phase is calculated as
the maximum current
according to IEC 60364. The
safety factor applied may
vary based on local
regulations or the best
practices, also upon the
characteristic the OCPD
selected.
II
%
<5
1.0
0.8 leading – 0.8 lagging
%
97.2
%
97
Isolated (HF transformer)
mW
50
2
August 2023
USM-00002-1.0

Advertisement

Table of Contents
loading

This manual is also suitable for:

Iq7a