13
TECHNICAL DATA
Name
ManipulationStatus
NonsafeCutOffPath01
NonsafeCutOffPath02
...
NonsafeCutOffPath08
ReferenceContourStatus
ResetRequiredCutOffPath01
ResetRequiredCutOffPath02
...
ResetRequiredCutOffPath08
RunModeactive
174
O P E R A T I N G I N S T R U C T I O N S | microScan3 – EtherCAT®
Use
Data type
Diagnostics
BOOL
Additional func‐
BOOL
tion
Additional func‐
BOOL
tion
Diagnostics
BOOL
Diagnostics
BOOL
Diagnostics
BOOL
Diagnostics
BOOL
Definition
Values
Manipulation
0 = no manipula‐
tion detected
Signals if manipulation
has been detected
1 = manipulation
and the safety outputs
detected
are therefore in the
OFF state, for example
because the device has
not detected an object
over a long period of
time.
Cut-off path 01 (Not
0 = OFF state,
safety-related)
detection in field
The signal is ON if
1 = ON state,
the currently monitored
field free
field in the cut-off path
is free.
Cut-off path 02 ... 08
0 = OFF state,
(Not safety-related)
detection in field
The signal is ON if
1 = ON state,
the currently monitored
field free
field in the cut-off path
is free.
1)
Reference contour
0 = contour in
monitoring
the set tolerance
band or refer‐
The safety laser scan‐
ence contour
ner does not detect any
monitoring not
contour within the con‐
active
figured tolerance band
of the reference con‐
1 = contour not
tour field. All safety out‐
in set tolerance
puts in the OFF state.
band
Reset required, Cut-off
0 = reset not
path 01
required
Signals whether the
1 = reset
device is waiting for a
required
reset signal to switch
safety-related cut-off
path 01 to the ON
state.
Reset required, Cut-off
0 = reset not
path 02 ... 08
required
Signals whether the
1 = reset
device is waiting for a
required
reset signal to switch
the respective safety-
related cut-off path to
the ON state.
1)
Status of safety func‐
0 = safety func‐
tion
tion paused.
Signals the operational
1 = safety func‐
status of the device.
tion is executed.
Safety implica‐
tion
Parameter with
implication for
the safety func‐
tion
Parameter with‐
out safety impli‐
cation
Parameter with‐
out safety impli‐
cation
Parameter with
implication for
the safety func‐
tion
Parameter with
implication for
the safety func‐
tion
Parameter with
implication for
the safety func‐
tion
Parameter with‐
out safety impli‐
cation
8025220/1L9Q/2023-08-14 | SICK
Subject to change without notice
Need help?