24 VDC & SCADA Connections
It is the customer's responsibility to provide their own wiring and conduit
for 24 VDC power and SCADA.* CDI recommends routing 24 VDC and
SCADA wiring through separate conduits. To route 24 VDC and SCADA into
the Bandit unit:
1. Standard Unit: Remove threaded
outlet plug(s) from the Killark junction
box as shown.
CAUTION: Induction from looped 24VDC power and relay cables could
trigger a false passage when stowed in close proximity to the Bandit
antenna. Position any cable loops as far from antenna as possible.
* SCADA (Supervisory Control and Data Acquisition) compatible standard relay
contacts can be used for passage annunciation (lights, horns, etc.) where an
unmanned passage must be monitored. SCADA-compatible 4-20mA option allows
connection to plant automation equipment using current loop interfacing.
CD52 Bandit (ATEX-IECEx and UKCA Certification) User Guide