SETUP & OPERATION

Power Options

Battery Operation
The Bandit in its standard configuration is powered by D-Cell alkaline
or lithium batteries. These batteries are required by ATEX-IECEx
standards to maintain system certification:
BATTERY
NON-RECHARGEABLE
DURACELL® PROCELL (PC1300)
SAFT LS 33600
RECHARGEABLE
SAFT MP176065
ANSMANN 5035362
NOTE: Battery types Duracell PC1300, SAFT LS 33600, and ANSMANN
5035362 are standard cells and may be obtained from CDI or other
distributors. The SAFT MP176065 cell is custom-configured for the CD52 and
must be purchased from CDI.
24VDC Operation
Always remove batteries before placing the unit into storage
Failure to do so may result in damage and may void warranty.
Operating from 24VDC power with batteries installed invalidates ATEX approval.
NOTE: In extreme cold (below -30°C) temperatures, 24 VDC will be
necessary to power the recommended internal heating element option
(see pg. 38).
NOTE: Bandits with optional 4-20mA Current Loop Interface configuration
require 24 VDC power. They cannot be powered by batteries.
See the Power Configuration chart on the following page to determine
which power option is required for your conditions.
CD52 Bandit (ATEX-IECEx and UKCA Certification) User Guide
WARNING:
and/or configuring for 24 VDC operation.
TYPE
QUAN.
ALKALINE
2 CELLS
Li-SOCl 2
1 CELL
Li-Ion
1 PACK
NiMH
2 CELLS
Page 11 of 52

SETUP AND OPERATION

MIN. LIFE SPAN
1 YEAR
1 YEAR
1 YEAR
6 MONTHS