CDI CD52 Bandit User Manual page 18

Non-intrusive pig passage signaler (atex-iecex and ukca certification)
Hide thumbs Also See for CD52 Bandit:
Table of Contents

Advertisement

SETUP AND OPERATION
Board Settings for 24 VDC Power
Set jumper to Pin 2.
Replace front cover.
Tamb = –40°C ~ +70°C (24 VDC OPERATION)
Tamb = –20°C ~ +53°C (DURACELL 1300 ALKALINE BATTERY OPERATION)
Tamb = –20°C ~ +64°C (ANSMANN 5035362 NiMH BATTERY OPERATION)
Tamb = –40°C ~ +70°C (SAFT LS 33600 LiSOCl
Tamb = –40°C ~ +70°C (SAFT MP176065 Li-Ion BATTERY OPERATION)
WARNING:
FOR SYSTEMS WITH TWO D-CELL BATTERY HOLDERS
USE ONLY DURACELL PC1300 OR ANSMANN 5035362 1.5V BATTERIES
FOR SYSTEMS WTH ONE D-CELL BATTERY HOLDER
USE ONLY SAFT LS33600 3.6V CELL
FOR SYSTEMS WITH NON-STANDARD BATTERY HOLDER
USE ONLY SAFT MP176065 3.6V BATTERY PACK
WARNING:
DO NOT MIX OLD WITH NEW BATTERIES
WARNING:
DO NOT OPEN WHEN ENERGIZED
WARNING:
EXPLOSION HAZARD – BATTERIES MUST ONLY BE CHANGED
IN AN AREA KNOWN TO BE NON-HAZARDOUS
WARNING:
DO NOT OPEN WHEN AN EXPLOSIVE GAS ATMOSPHERE
IS PRESENT
WARNING:
WHEN FITTED WITH RECHARGEABLE BATTERIES, REMOVE BATTERY
CELLS TO NON-EXPLOSIVE AREA FOR RECHARGING
CD52 Bandit (ATEX-IECEx and UKCA Certification) User Guide
ATEX/IECEx WARNINGS
Page 18 of 52
BATTERY OPERATION)
2

Advertisement

Table of Contents
loading

Table of Contents