CDI CD52 Bandit User Manual page 50

Non-intrusive pig passage signaler (atex-iecex and ukca certification)
Hide thumbs Also See for CD52 Bandit:
Table of Contents

Advertisement

SYSTEM SPECIFICATIONS
SYSTEM SPECIFICATIONS (cont.)
Line Sizes:
Pipe Wall Thickness:
NOTE: Where pipe wall thickness exceeds 25.4 mm [1 in.],
a custom magnet design may be required. Please consult CDI
for an evaluation of deployment options.
Pipe Mounting Assembly: Aluminum (316 Stainless Steel optional)
Banding and Buckles:
Contact Closure:
Contact Closure Current Capacity: 2 Amps at 30 Volts DC
Operational Temperature Ranges:
POWER SOURCE
24VDC
DURACELL® PROCELL (PC1300)
ANSMANN 5035362
SAFT LS 33600
SAFT MP176065
LineStat Satellite
Equipped System:
Total Passage Count:
Stored Passage
Information:
System Design Life:
Storage Life:
* Upper temperature limit determined by power option. Refer to Operational Temp
Range chart, pg. 12.
CD52 Bandit (ATEX-IECEx and UKCA Certification) User Guide
50.8 mm to 1524 mm [2 in. to 60 in.]
Up to 38.1 mm [1.5 in.]
201 Stainless Steel (316 Stainless Steel optional)
Electrically Isolated Double Pole – Double Throw
Available in normally-open or normally closed
configurations w/customer-specified relay dwell time
–30°C to 70°C* [–22°F to 158°F*]
10 (First In, First Out)
Time and Date of passages.
Information is stored through loss of power.
20 years
20 years
Page 50 of 52
RANGE
-40°C to +70°C
-20°C to +53°C
-20°C to +64°C
-40°C to +70°C
-40°C to +70°C