INSTALLATION

Armored Flex Cable Units

Bandit units configured with armored flex cable are shipped mounted
on a plywood sheet with webbing straps. Special unpacking procedures
should be followed:
NOTE: Prepare
an unobstructed
6 m x 6 m [20 ft x 20 ft]
area before unpacking.
Required tools/materials:
Screw gun or Phillips
screwdriver
1. Lift mounted assembly with webbing handles only.
2. Remove antenna base unit strap
using Phillips screw driver.
3. Uncoil cable. This requires
two (2) personnel. Person #1 will
hold antenna base (while supporting
cable) and walk in an ever-widening
circle. While walking, Person #1 will
continually untwist the antenna base
to prevent cable from kinking.
NOTE: Maintain a 152 mm [6 in.] minimum bend radius
to avoid kinking or breaking the aluminum cable armor.
Person #2 will be responsible for uncoiling cable at the plastic spool.
4. Startup procedure is identical to that of standard units.
SPECIFIC CONDITION OF USE:
The integral cable between the junction boxes/enclosures (the flex
cabling) shall be effectively clamped to prevent pulling or twisting.
CD52 Bandit (ATEX-IECEx and UKCA Certification) User Guide