20
IGNITION SYSTEM
20.1
Alternator - checking the stator winding
Stator winding - check the short circuit to ground (terminal 31)
–
Measure the resistance between the specified points.
Stator, connector HB pin 1 – Measuring point Ground (−)
Resistance
»
If the displayed value does not equal the setpoint value:
–
Change the stator.
Stator winding, measurement I - check the resistance
–
Measure the resistance between the specified points.
Stator, connector HB pin 1 – Stator, connector HB pin 2
Alternator
Resistance of stator winding at:
20 °C (68 °F)
»
If the displayed value does not equal the setpoint value:
–
Change the stator.
L00082-10
Stator winding, measurement II - check the resistance
–
Measure the resistance between the specified points.
Stator, connector HB pin 1 – Stator, connector HB pin 3
Alternator
Resistance of stator winding at:
20 °C (68 °F)
»
If the displayed value does not equal the setpoint value:
–
Change the stator.
L00082-10
≤ 1 Ω
≤ 1 Ω
304934-10
∞ Ω
220