Code Type
2475 Disturbance Stepper card X60 init position
2476 Disturbance Stepper card X60 not
2477 Disturbance Stepper card X60 overload
2478 Disturbance Stepper card X60 encoder
2479 Disturbance Stepper card X60 Current
2480 Disturbance Stepper card X60 Incorrect
2481 Disturbance Stepper card X60 reference
2483 Disturbance Stepper card X60 overcurrent • Replace the control
2484 Disturbance Stepper card X60 parameter
2485 Disturbance Stepper card X60 insulation
2487 Disturbance Stepper card X60 transport
2488 Disturbance Stepper card X60 reference
2501 Disturbance Stepper card X70 reference
2505 Disturbance Stepper card X70 stepper
190
Possible cause
not found
enabled
failure
sensor failure
stepping motor direction of
rotation
drive failure
initialization
error
interval failure
drive failure
drive timeout
motor blockage
Corrective
• Check for stiff movement
• Replace encoder
• Replace motor
• Replace the control
• Check for stiff movement
• Replace encoder
• Replace motor
• Replace encoder
• Replace the control
• Replace encoder
• Check if plugs have been mixed up
• Check and, if necessary, change machine
distributor connections
• Check for stiff movement
• Replace encoder
• Replace motor
• Perform software update
• Check selection of class
• Check the low-impedance connection at
motor phase and PE
• Replace encoder
• Replace sewing motor
• Perform software update
• Check selection of class
• Check for stiff movement
• Replace encoder
• Replace motor
• Check reference sensor
• Check for stiff movement
Operating Instructions D887 - 00.0 - 10/2022