DURKOPP ADLER M-TYPE DELTA D887 Operating Instructions Manual page 195

Table of Contents

Advertisement

Troubleshooting
Code Type
2672 Disturbance Stepper card X80 motor
2673 Disturbance Stepper card X80 motor
2674 Disturbance Stepper card X80 sewing
2675 Disturbance Stepper card X80 init position
2676 Disturbance Stepper card X80 not
2677 Disturbance Stepper card X80 overload
2678 Disturbance Stepper card X80 encoder
2679 Disturbance Stepper card X80 Current
2680 Disturbance Stepper card X80 Incorrect
2681 Disturbance Stepper card X80 reference
2683 Disturbance Stepper card X80 overcurrent • Replace the control
2684 Disturbance Stepper card X80 parameter
2685 Disturbance Stepper card X80 insulation
Operating Instructions D887 - 00.0 - 10/2022
Possible cause
overload/overvoltage/
overcurrent
encoder not connected
motor encoder not initialized
not found
enabled
failure
sensor failure
stepping motor direction of
rotation
drive failure
initialization
error
Corrective
• Check selection of class
• Replace the control
• Replace encoder
• Replace stepper motor
• Replace the control
• Perform software update
• Check selection of class
• Check for stiff movement
• Replace encoder
• Replace motor
• Replace the control
• Check for stiff movement
• Replace encoder
• Replace motor
• Replace encoder
• Replace the control
• Replace encoder
• Check if plugs have been mixed up
• Check and, if necessary, change machine
distributor connections
• Check for stiff movement
• Replace encoder
• Replace motor
• Perform software update
• Check selection of class
• Check the low-impedance connection at
motor phase and PE
• Replace encoder
• Replace sewing motor
193