Code Type
6365 Information Internal EEprom defective
6366 Information Internal EEprom defective
6367 Information Internal EEprom defective
7270 Information External CAN
9310 Disturbance Tape feeder not connected
9320 Disturbance Tape feeder in lowered
9330 Information Material thickness sensor
9340 Disturbance Bobbin control not
9910 Warning
9911
Warning
9912 Warning
9913 Warning
9914 Warning
9915 Warning
9916 Warning
198
Possible cause
and external data not valid
(emergency operating
features only)
and external data not valid
(emergency operating
features only)
position
not connected
connected.
Sewing stop
Power down
Restart necessary
Empty bobbin
Reset
Please Wait!
Erase internal Memory
Corrective
• Replace the control
• Replace the control
• Replace the control
• Check connection cables
• Perform software update
• Replace CAN slaves
• Check connection cables
• Perform software update
• Replace the control of the tape feeder
• No remedial action entered in translation
table
• Check connection cables
• Perform software update
• Replace material thickness sensor
• Check connection cables
• Perform software update
• Replace remaining thread monitor
• Check tilt sensor on machine
• Check 24V
• Replace the control
• The control is switched off
• Switching off the control
• Please insert a full bobbin
• Remove USB key!
• Please wait and do not remove USB key
• Delete the SD card. Continue with OK;
cancel with ESC