Printed Circuit Boards; Motor Control - ABB ACS800-04 Hardware Manual

Drive modules
Hide thumbs Also See for ACS800-04:
Table of Contents

Advertisement

30 Operation principle and hardware description

Printed circuit boards

The drive contains the following printed circuit boards as standard:
main circuit board (AINT)
motor control and I/O board (RMIO) with a fiber-optic link to the AINT board
input bridge control board (AINP)
input bridge protection board (AIBP) which includes snubbers for the thyristors
and varistors
power supply board (APOW)
gate driver control board (AGDR)
diagnostics and panel interface board (ADPI)
brake chopper control board (ABRC) with option +D150

Motor control

The motor control is based on the Direct Torque Control (DTC) method. Two phase
currents and DC link voltage are measured and used for the control. The third phase
current is measured for earth fault protection.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Acs800-04mAcs800-u4

Table of Contents