Efficiency; Energy Efficiency Data (Ecodesign); Cooling; Degrees Of Protection - ABB ACS800-04 Hardware Manual

Drive modules
Hide thumbs Also See for ACS800-04:
Table of Contents

Advertisement

Efficiency

Energy efficiency data (ecodesign)

Cooling

Method
Free space around the
unit
Cooling air flow

Degrees of protection

Prevention of unexpected start-up (+Q950): AGPS-21
board
Nominal input voltage
Input voltage range
(selected by jumper)
Nominal frequency
Current
Max. external fuse
Input connector X1
User connector 1, 2, 3
Output voltage
Nominal output current
X2 terminal block type
Ambient temperature
Relative humidity
Approvals
Approximately 98% at nominal power level
The efficiency is not calculated according to the ecodesign standard
IEC 61800-9-2.
Energy efficiency data according to IEC 61800-9-2 is available from the
ecodesign tool (https://ecodesign.drivesmotors.abb.com).
Internal fan, flow direction from front to top
ACS800-04/04M/U4 Cabinet Installation
Refer to
(English)].
IEC data
See
(page 99).
IP00 (UL type: open chassis)
115 V AC or 230 V AC
95...132 V AC (X3 on), 185...265 V AC (X4 on, default)
50/60 Hz
0.77 A at 115 V, 0.44 A at 230 V
16 A
2
3 × 2.5 mm
2
600 V, 25 A, 0.5...4 mm
24 V + 0.5 V
1.7 A (50 °C, 122 °F)
JST B3P-VH
0...50 °C (32...122 °F)
30...90%, no condensation allowed
CE, C-UL US listed
(20...12 AWG)
Technical data 121
[3AFE68360323

Advertisement

Table of Contents
loading

This manual is also suitable for:

Acs800-04mAcs800-u4

Table of Contents