Reliance electric GV3000 Instruction Manual page 73

A-c power modules
Hide thumbs Also See for GV3000:
Table of Contents

Advertisement

Table 9.1 - Resistance Checks (Continued)
60-100HP Drives
Input
Meter
Diode
Connection
Componentis OK if
No.
(+)
(-)
resistance (R)is:
Componentis defectiveif:
1
47
1L1
0.3 kohm <R< 8 kohm
Continuity (short circuit) or open when the meter is
2
147
112
connected with reversedpolarity
3
47
1L3
4
1L1
45
5
1L2
45
6
1L3
45
100-150HP Drives
Input
Meter
Diode
Connection
Componentis OK if
No.
(+)
(-)
resistance (R)is:
Componentis defective if:
1
47
1L1
R> 100 kohm
Continuity (short circuit)
2
47
1L2
3
47
1L3
4
1L1
45
5
1L2
45
6
1L3
45
1-60HP Drives
IGBT
Meter
No.
Connection
Componentis OK if
(+)
(-)
resistance (R)is:
Componentis defective if:
1
*
W/T3
50 <R< 10 Megohm
Continuity (short circuit) or open when the meter is
2
*
V/T2
connected with reversedpolarity
3
*
U/T1
4
W/T3
**
5
V/T2
**
6
U/T1
**
* (+) D-C Bus Volts power terminal
** (—) D-C Bus Volts power terminal
60-150HP Drives
IGBT
Meter
No.
Connection
Componentis OKif
(+)
(-)
resistance (R)is:
Componentis defectiveif:
1
47
WwW
0.3 kohm <R< 8 kohm
Continuity (short circuit) or open when the meter is
2
147
V
connectedwith reversed polarity
3
47
U
4
W
45
5
Vv
45
6
U
45
9-7

Advertisement