Reliance electric GV3000 Instruction Manual page 49

A-c power modules
Hide thumbs Also See for GV3000:
Table of Contents

Advertisement

6-2
Step 2.
Connect the three-phase A-C output power motor leadsto the proper output terminals
according to drive type.
On 1-60 HP drives, connect the motor leads to terminals U/T1, V/T2, W/T3 on the power
terminalstrip.
On 60-150 HP drives, connect the motor leads to terminals U, V, and W.
Step 3.
Tighten the three-phase A-C output power terminals to the proper torque according to drive
type as shownin table 5.1.