Safety switches series CTP-L1/2-... and CTA-L1/2-... are interlocking devices with guard locking solenoid (type 4). The
device meets the requirements according to EN IEC 60947-5-3. Devices with unicode evaluation possess a high coding
level, devices with multicode evaluation possess a low coding level.
In combination with a movable guard and the machine control, this safety component prevents the guard from being opened
while a dangerous machine function is being performed.
This means:
Starting commands that cause a dangerous machine function must become active only when the guard is closed and locked.
Ì
The guard locking must not be released until the dangerous machine function has ended.
Ì
Closing and locking a guard must not cause automatic starting of a dangerous machine function. A separate start command
Ì
must be issued. For exceptions, refer to EN ISO 12100 or relevant C-standards.
Devices from this series are also suitable for process protection.
Before the device is used, a risk assessment must be performed on the machine, e.g. in accordance with the following
standards:
EN ISO 13849-1
Ì
EN ISO 12100
Ì
IEC 62061
Ì
Correct use includes observing the relevant requirements for installation and operation, particularly based on the following
standards:
EN ISO 13849-1
Ì
EN ISO 14119
Ì
EN 60204-1
Ì
The safety switch is allowed to be operated only in conjunction with the intended EUCHNER actuator and the related connec-
tion components from EUCHNER. On the use of different actuators or other connection components, EUCHNER provides
no warranty for safe function.
Connection of several devices in a BR switch chain is permitted only using devices intended for series connection in a BR
switch chain. Check this in the instructions of the device in question.
Important!
The user is responsible for the proper integration of the device into a safe overall system. For this
Ì
purpose, the overall system must be validated, e.g. in accordance with EN ISO 13849-2.
It is only allowed to use components that are permissible in accordance with the table below.
Ì
Table 1:
Possible combinations for CTP/CTA components
Safety switch
CTP-L1/2-BR Unicode/Multicode
CTA-L1/2-BR Unicode/Multicode
Key to symbols
6
A-C-H-...
Combination possible
(translation of the original operating instructions) MAN20001654-01-03/23
Actuator
A-C-H-...-165497

Advertisement

Table of Contents
loading

Table of Contents