10.5.
Connector assignments
10.5.1. Connector assignment of safety switches CTP/CTA-...-BR-...-SAB-...
with plug connectors 2 x M12
Plug connector
(view of connection side)
2 x M12
X1.1
X1.2
X1.7
X1.3
X1.6
X1.4
X1.5
X1.8
X2.5
X2.1
X2.2
X2.4
X2.3
10.5.2. Connector assignment of safety switches CTP/CTA-...-BR-...-SA-...
with plug connector M12, 8-pin
Plug connector
(view of connection side)
1 x M12
1
2
7
3
6
4
5
8
10.5.3. Connector assignment of safety switches CTP/CTA-...-BR-...-APD-SA-...
with plug connector M12, 8-pin
Plug connector
(view of connection side)
1 x M12
1
2
7
3
6
4
5
8
MAN20001654-01-03/23 (translation of the original operating instructions)
Transponder-Coded Safety Switch CTP/CTA-L1/2-BR
Pin
Designation
X 1.1
FI1B
X 1.2
UB
X 1.3
FO1A
X 1.4
FO1B
X 1.5
OL/C
X 1.6
FI1A
X 1.7
0VUB
X 1.8
RST
X 2.1
IMM
X 2.2
OD
X 2.3
OI
X 2.4
IMP
X 2.5
-
1) Only for standard EUCHNER connecting cable
Pin
Designation
1
FI1B
2
UB
3
FO1A
4
FO1B
5
OD/C
6
FI1A
7
0V
8
IMP
1) Only for standard EUCHNER connecting cable
Pin
Designation
1
FI1B
2
UB
3
FO1A
4
FO1B
5
OD/C
6
FI1A
7
0V
8
UA
1) Only for standard EUCHNER connecting cable
Function
Enable input, channel B
Electronics operating voltage, 24 V DC
Safety output, channel A
Safety output, channel B
Guard lock monitoring output/communication
Enable input, channel A
Electronics operating voltage, 0 V DC
Reset input
Solenoid operating voltage, 0 V DC
Door position monitoring output
Diagnostic monitoring output
Solenoid operating voltage, 24 V DC
n.c.
Function
Enable input, channel B
Electronics operating voltage, 24 V DC
Safety output, channel A
Safety output, channel B
Door position monitoring output/communication
Enable input, channel A
Electronics and solenoid operating voltage, 0 V DC
Solenoid operating voltage, 24 V DC
Function
Enable input, channel B
Electronics operating voltage, 24 V DC
Safety output, channel A
Safety output, channel B
Door position monitoring output/communication
Enable input, channel A
Electronics and solenoid operating voltage, 0 V DC
Solenoid auxiliary voltage 24 V DC (connected internally to UB)
Operating Instructions
Conductor coloring
of connecting
cable
1)
WH
BN
GN
YE
GY
PK
BU
RD
BN
WH
BU
BK
GY
Conductor coloring
of connecting cable
1)
WH
BN
GN
YE
GY
PK
BU
RD
Conductor coloring
of connecting
cable
1)
WH
BN
GN
YE
GY
PK
BU
RD
21
EN