Operating Instructions Transponder-Coded Safety Switch CTP-I.-BP Contents About this document ..................... 4 1.1. Scope ............................4 1.2. Target group ..........................4 1.3. Key to symbols ..........................4 1.4. Supplementary documents ......................4 Correct use ......................5 Description of the safety function ................6 Exclusion of liability and warranty ................. 6 General safety precautions ...................
Page 3
Electrical function test ....................23 12.4. Factory reset ..........................23 System status table CTP-I.-BP ................24 Technical data ....................25 14.1. Technical data for safety switch CTP-I.-BP ..................25 14.2. Typical system times ........................26 14.3. Radio frequency approvals......................27 14.4. Dimension drawing for safety switch CTP… ..................28 14.5.
Transponder-Coded Safety Switch CTP-I.-BP 1. About this document 1.1. Scope These operating instructions apply to all CTP-I.-BP of version V1.3.X. These operating instructions, the document Safety information and any available data sheet form the complete user information for your device. 1.2. Target group Design engineers and installation planners for safety devices on machines as well as setup and servicing staff possessing special expertise in handling safety components.
EN 60204-1 Ì The safety switch is allowed to be operated only in conjunction with the intended EUCHNER actuator and the related connec- tion components from EUCHNER. On the use of different actuators or other connection components, EUCHNER provides no warranty for safe function.
Operating Instructions Transponder-Coded Safety Switch CTP-I.-BP 3. Description of the safety function Devices from this series feature the following safety functions: Monitoring of the guard position (interlocking device according to EN ISO 14119) Safety function (see chapter 6.6. Switching states on page 9): Ì...
Operating Instructions Transponder-Coded Safety Switch CTP-I.-BP 6. Function The device monitors the position of movable guards. Transponder-coded actuator The system consists of the following components: coded actuator (transponder) and switch. Whether the device learns the complete actuator code (unicode) or not (multi- code) depends on the respective version.
Operating Instructions Transponder-Coded Safety Switch CTP-I.-BP 6.3.4. Escape release signal OER The escape release signal is present if the device has been released manually (see chapter 7. Manual release on page 10). The signal is reset if the guard locking is re-activated or the reset function has been activated.
Switching states The detailed switching states for your switch can be found in the system status table (see chapter 13. System status table CTP-I.-BP on page 24). All safety outputs, signals and display LEDs are described there. Guard open Guard closed and locked...
Operating Instructions Transponder-Coded Safety Switch CTP-I.-BP 7. Manual release Important! No further release functions can be retrofitted on Extended variants with control elements in position 1 (S1) and position 2 (S2). Some situations require the guard locking to be released manually (e.g. malfunctions or an emergency). A function test must be performed after release.
Operating Instructions Transponder-Coded Safety Switch CTP-I.-BP 7.1.2. Actuating auxiliary key release On devices with auxiliary key release (can be retrofitted), simply turn the key to release. Function as for auxiliary release. For mounting, see the auxiliary key release supplement. 7.2.
Operating Instructions Transponder-Coded Safety Switch CTP-I.-BP 7.3. Escape release (optional) This permits opening of a locked guard from the danger zone without tools (see chapter 14.4. Dimension drawing for safety switch CTP… on page 28). Important! It must be possible to actuate the escape release manually from inside Ì...
Operating Instructions Transponder-Coded Safety Switch CTP-I.-BP 7.4.1. Laying wire front release Important! Loss of the release function due to mounting errors, damage or wear. Ì Check the release function every time after mounting. Ì When routing the wire front release, ensure that it operates smoothly.
Operating Instructions Transponder-Coded Safety Switch CTP-I.-BP 9. Mounting CAUTION Safety switches must not be bypassed (bridging of contacts), turned away, removed or otherwise rendered ineffective. Observe EN ISO 14119:2013, section 7, for information about reducing the possibilities for bypassing Ì an interlocking device.
Operating Instructions Transponder-Coded Safety Switch CTP-I.-BP 10. Electrical connection WARNING In the event of a fault, loss of the safety function due to incorrect connection. To ensure safety, both safety outputs FO1A and FO1B must always be evaluated. Ì Monitoring outputs must not be used as safety outputs.
Operating Instructions Transponder-Coded Safety Switch CTP-I.-BP 10.1. Notes about Important! This device is intended to be used with a Class 2 power source in accordance with UL1310. Ì As an alternative an LV/C (Limited Voltage/Current) power source with the following properties can...
Use connection components and connecting cables from EUCHNER. Ì On the use of other connection components, the requirements in the following table apply. EUCHNER Ì provides no warranty for safe function in case of failure to comply with these requirements.
RST input for at least 3 s. The RST input must be connected to 0 V if it is not used. If there is an internal error (see chapter 13. System status table CTP-I.-BP on page 24), the reset does not work.
For the test pulse duration of your safety switch, refer to chapter 14. Technical data on page 25. A detailed example of connecting and setting the parameters of the control system is available for many devices at www.euchner.com in the area Downloads/Applications/CTP..The features of the respective device are dealt with there in greater detail.
Operating Instructions Transponder-Coded Safety Switch CTP-I.-BP 11. Using communication data A BR/IO-Link Gateway is required to use the device’s communication data and forward them to a higher-level bus system. The following devices are suitable: GWY-CB-1-BR-IO (BR/IO-Link Gateway) Ì ESM-CB (safety relay with integrated BR/IO-Link Gateway) Ì...
Operating Instructions Transponder-Coded Safety Switch CTP-I.-BP 11.3.2. Acyclical data (device data and events) After one of the commands listed below is sent, the requested data are provided via the IO-Link Gateway. The following applies to CTP devices of version V1.3.X: The reply message always consists of 8 bytes in big endian format.
Operating Instructions Transponder-Coded Safety Switch CTP-I.-BP 12. Setup 12.1. LED displays You will find a detailed description of the signal functions in chapter 13. System status table CTP-I.-BP on page 24. Color STATE green LOCK yellow STATE LOCK 12.2. Teaching-in actuator (only for unicode evaluation) The actuator must be allocated to the safety switch using a teach-in function before the system forms a functional unit.
Operating Instructions Transponder-Coded Safety Switch CTP-I.-BP 12.3. Functional check WARNING Danger of fatal injury as a result of faults in installation and functional check. Before carrying out the functional check, make sure that there are no persons in the danger zone.
Operating Instructions Transponder-Coded Safety Switch CTP-I.-BP 13. System status table CTP-I.-BP LED indicator Output Operating mode State 5 Hz Self-test after power-up Self-test 5 Hz 1 x No communication with the BR/IO-Link Gateway closed Normal operation, door closed and locked open Normal operation, door open, ready for guard locking...
Operating Instructions Transponder-Coded Safety Switch CTP-I.-BP 14. Technical data NOTICE If a data sheet is available for the product, the information on the data sheet applies. 14.1. Technical data for safety switch CTP-I.-BP Value Parameter Unit min. typ. max. General...
Operating Instructions Transponder-Coded Safety Switch CTP-I.-BP Value Parameter Unit min. typ. max. Reliability values acc. to EN ISO 13849-1 Mission time years Monitoring of the guard position Category Performance Level (PL) 5.38 x 10 1) Dependent on the actuator used 2) Trip characteristic medium slow-blow...
Operating Instructions Transponder-Coded Safety Switch CTP-I.-BP 14.3. Radio frequency approvals FCC ID: 2AJ58-13 22052-13 FCC/IC-Requirements This device complies with part 15 of the FCC Rules and with Industry Canada’s licence-exempt RSSs. Operation is subject to the following two conditions: 1) This device may not cause harmful interference, and 2) this device must accept any interference received, including interference that may cause undesired operation.
Operating Instructions Transponder-Coded Safety Switch CTP-I.-BP 14.4. Dimension drawing for safety switch CTP… Version with plug connector M12 With escape release The actuator shaft for the escape release can be extended using extensions (max. 94 mm) Basic position for escape release ∅ 5.3 (4x), 1.4 Nm...
Page 29
Operating Instructions Transponder-Coded Safety Switch CTP-I.-BP With auxiliary key release With release, automatic return max. 50 With emergency release With wire front release (bowden) 21,5 32,4 MAN20001421-03-03/23 (translation of the original operating instructions)
Operating Instructions Transponder-Coded Safety Switch CTP-I.-BP 14.5. Technical data for actuator CTP-… Parameter Value Unit min. typ. max. Housing material Fiber reinforced plastic Weight 0.03 … 0.06 (depending on version) Ambient temperature °C Degree of protection IP65/IP67/IP69/IP69K Mechanical life 1 x 10 Locking force (ISO 14119)
Page 31
Operating Instructions Transponder-Coded Safety Switch CTP-I.-BP Dimension drawing Min. door radius [mm] Order no./item 37,5 122667 A-C-H-W-SST-122667 12,45 Bent, upward max. 28 122668 A-C-H-W-SST-122668 5,25 Bent, downward MAN20001421-03-03/23 (translation of the original operating instructions)
Page 32
Operating Instructions Transponder-Coded Safety Switch CTP-I.-BP Dimension drawing Min. door radius [mm] Order no./item 3,25 122671 A-C-H-RL-LS-122671 max. 28 X = 53 mm (122671, 122672) X = 49 mm (122669, 122670) 122672 A-C-H-RR-LS-122672 122675 A-C-H-RO-LS-122675 max. 28 X = 41 mm (122673, 122674)
18. Declaration of conformity The declaration of conformity is part of the operating instructions. The complete EU declaration of conformity can also be found at www.euchner.com. Enter the order number of your device in the search box. The document is available under Downloads.
Page 34
Operating Instructions Transponder-Coded Safety Switch CTP-I.-BP (translation of the original operating instructions) MAN20001421-03-03/23...
Page 35
Operating Instructions Transponder-Coded Safety Switch CTP-I.-BP MAN20001421-03-03/23 (translation of the original operating instructions)