Laying Wire Front Release; Changing The Approach Direction - EUCHNER CTP-L1-BR Unicode Operating Instructions Manual

Transponder-coded safety switch with guard locking
Table of Contents

Advertisement

Operating Instructions
Transponder-Coded Safety Switch CTP/CTA-L1/2-BR

7.4.1. Laying wire front release

Important!
Loss of the release function due to mounting errors, damage or wear.
Ì
Check the release function every time after mounting.
Ì
When routing the wire front release, ensure that it operates smoothly.
Ì
Observe the min. bending radius (100 mm) and minimize the number of bends.
Ì
The switch is not allowed to be opened.
Ì
Please observe the notes on the corresponding data sheets.
Ì

8. Changing the approach direction

The approach direction needs to be changed only if the switch is to be approached from the rear.
Proceed as follows:
1. Remove the screws from the safety switch.
2. Set the required direction.
3. Tighten the screws with a torque of 1.2 Nm.
Fig. 1:
Changing the approach direction
16
D
A
C
B
(translation of the original operating instructions) MAN20001654-01-03/23

Advertisement

Table of Contents
loading