Connection Of A Single Ctp/Cta-Br (Separate Operation) - EUCHNER CTP-L1-BR Unicode Operating Instructions Manual

Transponder-coded safety switch with guard locking
Table of Contents

Advertisement

11. Connection of a single CTP/CTA-BR (separate operation)

If a single CTP/CTA-BR is used, connect the device as shown in Fig. 6. The monitoring outputs can be routed to a control
system.
The following applies to devices with RST input: The switch can be reset using the RST input. To do this, a voltage of 24 V
is applied to the RST input for at least 3 s. The RST input must be connected to 0 V if it is not used.
If there is an internal error (see chapter 15. System status table CTP/CTA-L1/2-BR on page 38), the reset does not work.
WARNING
In the event of a fault, loss of the safety function due to incorrect connection.
To ensure safety, both safety outputs FO1A and FO1B must always be evaluated.
Ì
Important!
The example shows only an excerpt that is relevant for connection of the CTP/CTA system. The
Ì
example illustrated here does not show complete system planning. The user is responsible for safe
integration into the overall system. Detailed application examples can be found at www.euchner.com.
Simply enter the order number of your switch in the search box. You will find all available connection
examples for the device in Downloads.
24V DC
0 V
-S2
Fig. 6:
Connection example for separate operation, version with plug connectors 2xM12
MAN20001654-01-03/23 (translation of the original operating instructions)
Transponder-Coded Safety Switch CTP/CTA-L1/2-BR
1
-F1
-F2
2
13
-S1
14
IMP
X2:4
Read Head
X2:1
X2:5
IMM
n.c.
1
2
UB
RST
X1:2
X1:8
Monitoring Outputs
Door
Locking
Monitoring
active
Diagnostic
X1:7
X2:2
X1:5
0 V
UB
OD
OL
Operating Instructions
FI1A
FI1B
X1:6
X1:1
Safety Inputs
Safety Outputs
X2:3
X1:3
X1:4
OI
FO1A
FO1B
Connected load
24V DC
0 V
EN
25