Initial Start-Up; Menu Structure - Kaco blueplanet 29.0 TL3 Operating Instructions Manual

Hide thumbs Also See for blueplanet 29.0 TL3:
Table of Contents

Advertisement

Configuration and Operation
8.2

Initial start-up

EN
EN
When started for the first time, the inverter displays the configuration assistant. It takes you through the settings
necessary for the initial start-up.
NOTE
After configuration is completed, the configuration assistant does not appear again when the
inverter is restarted. You can then change the country setting only in the password-protected param-
eter menu. The other settings can still be changed in the Settings menu.
NOTE
The DC power supply must be guaranteed during initial start-up.
The sequence of the settings required for initial start-up is present in the configuration assistant.
Navigation
In order to select a setting, press the up and down buttons.
To select the next menu item, press the Enter button.
To return to the most recently selected menu item, press the ESC button.
Set the required settings.
Press the Enter button in the last menu item.
Initial configuration
Select the menu language.
Select the country of operation with grid type.
Set the date and time.
To store the set operator country and grid type permanently, confirm these settings with "Yes".
»
You have completed the initial configuration. The inverter begins to operate.
8.3

Menu structure

8.3.1
Display on the LCD
1
3
Figure 42: Main menu
Key
1
Selected menu item
2
Name of the active menu level
Page 34
2
4
3
Menu items of the active menu level
4
Menu items of the next lower menu level
Operating Instructions KACO blueplanet 29.0TL3

Advertisement

Table of Contents
loading

Table of Contents