Advertisement

Application note – Installation and using APP
English version
Authorised electrician
Important safety instructions
Android-APP
These instructions form part of the product and must be observed. They must also be stored in a place which is always freely
accessible. The copyright for these operating instructions is held solely by KACO new energy GmbH.
iOS-APP
KACO blueplanet 3.0 NX3 M2
KACO blueplanet 5.0 NX3 M2
KACO blueplanet 8.0 NX3 M2
KACO blueplanet 10.0 NX3 M2
KACO blueplanet 15.0 NX3 M2
KACO blueplanet 20.0 NX3 M2
KACO blueplanet 25.0 NX3 M3
KACO blueplanet 30.0 NX3 M3
KACO blueplanet 33.0 NX3 M3

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the blueplanet 25.0 NX3 M3 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Kaco blueplanet 25.0 NX3 M3

  • Page 1 Android-APP iOS-APP These instructions form part of the product and must be observed. They must also be stored in a place which is always freely accessible. The copyright for these operating instructions is held solely by KACO new energy GmbH.
  • Page 2: Table Of Contents

    Contents WLAN Network Configuration ..........................1 Authorization ......................................... 1 Network configuration ....................................... 2 Change the router ........................................ 3 Set the time zone to Wi-Fi stick ..................................4 Inverter Parameters Settings ..........................5 Connect to Wi-Fi stick ......................................5 2.1.1 Connect Wi-Fi stick directly through the Wi-Fi stick’s hotspot ..................... 5 2.1.2 Connect Wi-Fi stick through the router ..............................
  • Page 3: Wlan Network Configuration

    Fig. 2: Location permission Fig. 3: Device information permission Fig. 4: Pictures and video Fig. 5: Location services Page 1 KACO blueplanet 3.0 NX3 M2 - KACO blueplanet 20.0 NX3 M2 + KACO blueplanet 25.0 NX3 M3 - KACO blueplanet 33.0 NX3 M3...
  • Page 4: Network Configuration

    Fig. 6: Home page Fig. 7: Scan QR code Fig. 8: Network configuration Fig. 9: Successful configuration KACO blueplanet 3.0 NX3 M2 - KACO blueplanet 20.0 NX3 M2 + KACO blueplanet 25.0 NX3 M3 - KACO blueplanet 33.0 NX3 M3 Page 2...
  • Page 5: Change The Router

    Wi-Fi stick’s hotspot named the Wi-Fi stick’s serial number in your WLAN list. You can connect to the Wi-Fi stick hotspot with the registration code on the label as password. Fig. 10: Change network Page 3 KACO blueplanet 3.0 NX3 M2 - KACO blueplanet 20.0 NX3 M2 + KACO blueplanet 25.0 NX3 M3 - KACO blueplanet 33.0 NX3 M3...
  • Page 6: Set The Time Zone To Wi-Fi Stick

    3 Click the “>” button of the time item, choose the Time Zone and click the OK button. KACO blueplanet 3.0 NX3 M2 - KACO blueplanet 20.0 NX3 M2 + KACO blueplanet 25.0 NX3 M3 - KACO blueplanet 33.0 NX3 M3...
  • Page 7: Inverter Parameters Settings

    › Close the Mobile Data of phone and come back to app to click on “Scan device” to get the Wi-Fi stick. Page 5 KACO blueplanet 3.0 NX3 M2 - KACO blueplanet 20.0 NX3 M2 + KACO blueplanet 25.0 NX3 M3 - KACO blueplanet 33.0 NX3 M3...
  • Page 8: Connect Wi-Fi Stick Through The Router

    Wi-Fi stick in list after multiple attempts, you can close the router to connect to Wi-Fi stick directly through the Wi-Fi stick's hotspot. KACO blueplanet 3.0 NX3 M2 - KACO blueplanet 20.0 NX3 M2 + KACO blueplanet 25.0 NX3 M3 - KACO blueplanet 33.0 NX3 M3...
  • Page 9: Inverter Parameters Settings

    You have removed a single inverter/multiple inverters connected to the Wi-Fi stick. › You have replaced a single inverter/multiple inverters connected to the Wi-Fi stick. Page 7 KACO blueplanet 3.0 NX3 M2 - KACO blueplanet 20.0 NX3 M2 + KACO blueplanet 25.0 NX3 M3 - KACO blueplanet 33.0 NX3 M3...
  • Page 10 The inverter-specific passcode can be obtained from KACO Service.: Fig. 14: Inverter passcode KACO blueplanet 3.0 NX3 M2 - KACO blueplanet 20.0 NX3 M2 + KACO blueplanet 25.0 NX3 M3 - KACO blueplanet 33.0 NX3 M3 Page 8...
  • Page 11: Enabling Inverter Functions

    To select the required local grid code please click on ‘ Grid Standard Settings’ . The next page will display the country standard list. Here you can choose the right grid standard. Fig. 17: Grid Standard Page 9 KACO blueplanet 3.0 NX3 M2 - KACO blueplanet 20.0 NX3 M2 + KACO blueplanet 25.0 NX3 M3 - KACO blueplanet 33.0 NX3 M3...
  • Page 12: Inverter Gird Parameter Setting: Power Up

    The appropriate voltage range and frequency range for starting can be set according to the requirements of the local grid company. Fig. 18: Parameter settings for starting KACO blueplanet 3.0 NX3 M2 - KACO blueplanet 20.0 NX3 M2 + KACO blueplanet 25.0 NX3 M3 - KACO blueplanet 33.0 NX3 M3 Page 10...
  • Page 13: Inverter Gird Parameter Setting : Voltage Protection

    3. The first threshold tripping time ≤ The second threshold tripping time ≤ The third threshold tripping time Fig. 19: Grid voltage protection Page 11 KACO blueplanet 3.0 NX3 M2 - KACO blueplanet 20.0 NX3 M2 + KACO blueplanet 25.0 NX3 M3 - KACO blueplanet 33.0 NX3 M3...
  • Page 14: Inverter Gird Parameter Setting: Frequency Protection

    3. The first threshold tripping time ≤ The second threshold tripping time ≤ The third threshold tripping time Fig. 20: Grid frequency protection KACO blueplanet 3.0 NX3 M2 - KACO blueplanet 20.0 NX3 M2 + KACO blueplanet 25.0 NX3 M3 - KACO blueplanet 33.0 NX3 M3...
  • Page 15: Inverter Gird Parameter Setting: Reconnection Time

    Fig. 21: Reconnection time Page 13 KACO blueplanet 3.0 NX3 M2 - KACO blueplanet 20.0 NX3 M2 + KACO blueplanet 25.0 NX3 M3 - KACO blueplanet 33.0 NX3 M3...
  • Page 16: Inverter Active Power Setting: Power Limit

    The grid company maybe requires reduction of active power on set point. You can set ‘Active power limit’ according to the requirement. Fig. 22: Power limit KACO blueplanet 3.0 NX3 M2 - KACO blueplanet 20.0 NX3 M2 + KACO blueplanet 25.0 NX3 M3 - KACO blueplanet 33.0 NX3 M3 Page 14...
  • Page 17: Inverter Active Power Setting : Over-Frequency Curve

    Min. delay time for active power release is the delay time that the active power can increase after the frequency below freset. Page 15 KACO blueplanet 3.0 NX3 M2 - KACO blueplanet 20.0 NX3 M2 + KACO blueplanet 25.0 NX3 M3 - KACO blueplanet 33.0 NX3 M3...
  • Page 18 Fig. 23: Over-frequency curve KACO blueplanet 3.0 NX3 M2 - KACO blueplanet 20.0 NX3 M2 + KACO blueplanet 25.0 NX3 M3 - KACO blueplanet 33.0 NX3 M3 Page 16...
  • Page 19: Inverter Active Power Setting: Over-Voltage Curve

    Min. delay time for active power release is the delay time that the active power can increase after the voltage below U reset. Page 17 KACO blueplanet 3.0 NX3 M2 - KACO blueplanet 20.0 NX3 M2 + KACO blueplanet 25.0 NX3 M3 - KACO blueplanet 33.0 NX3 M3...
  • Page 20 Fig. 24: Over-voltage curve KACO blueplanet 3.0 NX3 M2 - KACO blueplanet 20.0 NX3 M2 + KACO blueplanet 25.0 NX3 M3 - KACO blueplanet 33.0 NX3 M3 Page 18...
  • Page 21: Inverter Reactive Power Setting: Running Mode

    95% of the nominal value is reached. Fig. 25: Reactive running mode Page 19 KACO blueplanet 3.0 NX3 M2 - KACO blueplanet 20.0 NX3 M2 + KACO blueplanet 25.0 NX3 M3 - KACO blueplanet 33.0 NX3 M3...
  • Page 22: Inverter Reactive Power Setting: Fixed Power Factor

    2.2.12 Inverter reactive power setting: fixed power factor The fixed displacement factor cosφ can be set. Fig. 26: Fixed power factor KACO blueplanet 3.0 NX3 M2 - KACO blueplanet 20.0 NX3 M2 + KACO blueplanet 25.0 NX3 M3 - KACO blueplanet 33.0 NX3 M3 Page 20...
  • Page 23: Inverter Reactive Power Setting: Cos(Φ) - P Curve

    Deactivation threshold as a percentage of Un corresponds to ‘lock-out’ voltage Fig. 27: Cos curve Φ Page 21 KACO blueplanet 3.0 NX3 M2 - KACO blueplanet 20.0 NX3 M2 + KACO blueplanet 25.0 NX3 M3 - KACO blueplanet 33.0 NX3 M3...
  • Page 24: Inverter Reactive Power Setting: Fixed Q

    The fixed reactive power as a percentage of Pn can be set. Fig. 28: Fixed Q KACO blueplanet 3.0 NX3 M2 - KACO blueplanet 20.0 NX3 M2 + KACO blueplanet 25.0 NX3 M3 - KACO blueplanet 33.0 NX3 M3 Page 22...
  • Page 25: Inverter Reactive Power Setting: Q-U Curve

    Deactivation threshold as a percentage of Pn corresponds to ‘lock-out’ active power. Fig. 29: Q-U curve Page 23 KACO blueplanet 3.0 NX3 M2 - KACO blueplanet 20.0 NX3 M2 + KACO blueplanet 25.0 NX3 M3 - KACO blueplanet 33.0 NX3 M3...
  • Page 26: Inverter Parameters Report

    After grid parameter setting, press “Inverter Parameter Report” menu, and gird parameter will be shown on page. Press “Export PDF” button, the export file is located as a pdf file in “kaco.report” folder on your smart phone Fig. 30: Parameters report...
  • Page 27: Inverter Real Time Data

    You have removed a single inverter/multiple inverters connected to the Wi-Fi stick. › You have replaced a single inverter/multiple inverters connected to the Wi-Fi stick. Page 25 KACO blueplanet 3.0 NX3 M2 - KACO blueplanet 20.0 NX3 M2 + KACO blueplanet 25.0 NX3 M3 - KACO blueplanet 33.0 NX3 M3...
  • Page 28: Inverter's Details

    Error code It is “N/A”, when no error happened. Fig. 15: Inverter real time data KACO blueplanet 3.0 NX3 M2 - KACO blueplanet 20.0 NX3 M2 + KACO blueplanet 25.0 NX3 M3 - KACO blueplanet 33.0 NX3 M3 Page 26...
  • Page 29: Firmware Update

    3 Firmware Update 3.1 Wi-Fi stick firmware update  Current firmware package is available on the KACO homepage and does not match the firmware version on the unit(s). 1 Download the firmware "KACO_NX3_Vxx.zip" with the required *.bin files from our homepage www.kaco-...
  • Page 30: Inverter Firmware Update

    The whole process will take about 10 minutes at least. After 10 minutes, you can check the firmware with the tool app. The *bin versions must completely match the versions from the firmware path. KACO blueplanet 3.0 NX3 M2 - KACO blueplanet 20.0 NX3 M2 + KACO blueplanet 25.0 NX3 M3 - KACO blueplanet 33.0 NX3 M3...
  • Page 31 Werner-von-Siemens-Allee 1 · 74172 Neckarsulm · Germany · Tel. +49 7132 · info@kaco-newenergy.de · www.kaco-newenergy.de 3818-0...

Table of Contents