Display, Full Screen Monitoring, Audible Warning (buzzer), Notify Surveillance Center, Trigger
Alarm Output, and Send Email.

6.4.1 Configure Auto-Switch Full Screen Monitoring

When an alarm is triggered, the local monitor displays in full screen the video image from the
alarming channel configured for full screen monitoring. And when the alarm is triggered
simultaneously in several channels, you must configure the auto-switch dwell time.
Note
Auto-switch will terminate once the alarm stops and back to the live view interface.
Steps
1. Go to System → Live View → General.
2. Set the event output and dwell time.
Event Output
Select the output to show the event video.
Full Screen Monitoring Dwell Time
Set the time in seconds to show the alarm event screen. If alarms are triggered
simultaneously in several channels, their full-screen images will be switched at an interval of
10 seconds (default dwell time).
3. Go to the Linkage Action interface of the alarm detection (e.g., motion detection, video
tampering, face detection, etc.).
4. Select the Full Screen Monitoring alarm linkage action.
5. Select the channel(s) in Trigger Channel for full screen monitoring.

6.4.2 Configure Audio Warning

The audio warning has the system to trigger an audible beep when an alarm is detected.
Steps
1. Go to System → View → General.
2. Enable the audio output and set the volume.
3. Go to Linkage Action interface of the alarm detection (e.g., motion detection, video tampering,
face detection, etc.).
4. Select the Audio Warning alarm linkage action.

6.4.3 Notify Surveillance Center

The device can send an exception or alarm signal to the remote alarm host when an event occurs.