Front Panel - ESAB Miggytrac 2000 Instruction Manual

Table of Contents

Advertisement

GB
4.2

Front panel

1
Welding speed: Program the weld speed in cm/minute. For speeds over 100 cm/min a com-
2
Menu selector:
3
Bead length:
4
Bead distance:
5
Craterfill time:
6
Backfill:
7
Chain intermit-
tent welding:
8
Direction:
9
Welding:
10
Voltage poten-
tiometer:
11
Wire feed po-
tentiometer:
fhb2o1ea
V
ma is lighting after the last figure.
Switch between the menus for the programming of chain intermittent weld-
ing, craterfill time and backfill.
Program the length of the bead in cm for chain intermittent
Program the distance between the beads for chain intermittent welding.
Program the standstill time of the carriage during the craterfilling. Can also
be used for programming the pause/cooling time before the carriage is to
execute a backfill.
Program the reversing length of the carriage to fill a crater at the end of a
bead.
Switch for the selection of chain intermittent welding. Green LED indicates
continuous welding.
Switch for selecting the direction of the carriage motion. The selection shall
be done before start.
Start/stop switch for the power source connected.
Potentiometer for remote control of welding voltage.
Potentiometer for remote control of wire feed speed (welding current).