DIRECTIVE DECLARATION OF CONFORMITY ESAB AB, Welding Equipment, SE--695 81 Laxå, Sweden, gives its unreserved guarantee that weld- ing power source Origo Mig 410 / Origo Mig 510 from serial number 627 complies with standard IEC/EN 60974--1, in accordance with the requirements of directive (73/23/EEC) and addendum (93/68/EEC) and with standard IEC/EN 60974--10 in accordance with the requirements of directive (89/336/EEC) and addendum (93/68/EEC).
Page 4
WARNING! Read and understand the instruction manual before installing or operating. WARNING ARC WELDING AND CUTTING CAN BE INJURIOUS TO YOURSELF AND OTHERS. TAKE PRECAU- TIONS WHEN WELDING. ASK FOR YOUR EMPLOYER’S SAFETY PRACTICES WHICH SHOULD BE BASED ON MANUFACTURERS’ HAZARD DATA. ELECTRIC SHOCK - - Can kill Install and earth the welding unit in accordance with applicable standards.
The machines can be fitted with an instrument for display of current and voltage. It incorporates a hold function and can be calibrated. The machines can be fitted with a flow guard. ESAB’s accessories for the product can be found on page 20. Equipment The power source is supplied with:...
Placing Position the welding power source such way that its cooling air inlets and outlets are not obstructed. Assembly of components WARNING! During transport, the rear wheels of the power source are in their forward position. Before use, place the wheels in their rear position. - - 7 - - mi410,510e...
Assembly of counter balance Assemble the stabilizer + CB KIT if the counter balance is to be installed on machine. The stabilizer + CB KIT is an accessory. Ordering number you can find on page 21. Attention! Utilization of counter balance without stabilizer may cause the machine tipping over.
Mains power supply Check that the unit is connected to the correct mains power supply voltage, and that it is protected by the correct fuse size. A protective earth connection must be made, in accordance with regulations. Rating plate with supply connection data Origo Mig 410 3∼...
NOTE! Cooling water connections only available on certain models. * Indicating loss of coolant, only when water flow guard is used, see point 6.5 ** ELP = ESAB Logic Pump, see point 6.4. - - 11 - - mi410,510e...
Water connection The Origo Feed has a sensor ELP, ESAB Logic Pump, which senses whether the water hoses of the welding gun are connected. When a water--cooled welding gun is connected, the water pump is active. For the Feeds the pump supply switch on the power source should be left in position ”0/ELP”.
MAINTENANCE Regular maintenance is important for safe, reliable operation. Note! All guarantee undertakings from the supplier cease to apply if the customer himself attempts any work in the product during the guarantee period in order to rectify any faults. Inspection and cleaning Check regularly that the power source is free from dirt.