Summary of Contents for ESAB Origo Mig L305

  • Page 1 Origo™ Mig L305                                   Mig L405 Instruction manual Valid for: serial no. 628-, 647-, 211-xxx-xxxx 0349 301 124 GB 20170310...
  • Page 3: Table Of Contents

    MAINTENANCE ..................... 16 Inspection and cleaning................Topping up the coolant ................TROUBLESHOOTING ................... 18 ORDERING SPARE PARTS ................19 CLEANING......................DIAGRAM ......................ORDERING NUMBERS ..................ACCESSORIES ....................Rights reserved to alter specifications without notice. 0349 301 124 © ESAB AB 2017...
  • Page 4: Safety

    Data Sheets (SDSs). Safety precautions Users of ESAB equipment have the ultimate responsibility for ensuring that anyone who works on or near the equipment observes all the relevant safety precautions. Safety precautions must meet the requirements that apply to this type of equipment. The following recommendations should be observed in addition to the standard regulations that apply to the workplace.
  • Page 5 • Protect your eyes and body. Use the correct welding screen and filter lens and wear protective clothing. • Protect bystanders with suitable screens or curtains. NOISE - Excessive noise can damage hearing Protect your ears. Use earmuffs or other hearing protection. 0349 301 124 - 5 - © ESAB AB 2017...
  • Page 6 For further information contact the nearest ESAB dealer. ESAB has an assortment of welding accessories and personal protection equipment for purchase. For ordering information contact your local ESAB dealer or visit us on our website. 0349 301 124 - 6 -...
  • Page 7: Introduction

    The power units are fan-cooled and equipped with thermal overload protection. They can be fitted with an instrument that displays current and voltage. It incorporates a hold function and can be calibrated. ESAB accessories for the product can be found in the "ACCESSORIES" chapter of this manual. Equipment The power source is supplied with: •...
  • Page 8: Technical Data

    IP 23 Application class Coolant ESAB ready mixed coolant Duty cycle The duty cycle refers to the time as a percentage of a ten-minute period that you can weld or cut at a certain load without overloading. The duty cycle is valid for 40 °C / 104 °F, or below.
  • Page 9: Installation

    The stabilizer + CB KIT is an accessory. See "ACCESORIES" chapter for order number. NOTE! Use of a counter balance without stabilizer may cause the welding equipment to tip over. 0349 301 124 - 9 - © ESAB AB 2017...
  • Page 10: Assembly Of Components

    4 INSTALLATION Assembly of components WARNING! During transport, the rear wheels of the power source are in their forward position Before use, place the wheels in their rear position. 0349 301 124 - 10 - © ESAB AB 2017...
  • Page 11: Electrical Installation

    4 INSTALLATION Electrical installation 0349 301 124 - 11 - © ESAB AB 2017...
  • Page 12: Mains Power Supply

    4 x 2.5 Cable area mm Fuse, slow A L405 3~ 50 Hz 3~ 50/60 Hz 3~ 50 Hz 3~ 60 Hz 3~ 60 Hz Voltage V 400/415 440/460 Current A 0349 301 124 - 12 - © ESAB AB 2017...
  • Page 13 The mains cable areas and fuse sizes as shown above are in accordance with Swedish regulations. For other regions, supply cables must be suitable for the application and meet local and national regulations. 0349 301 124 - 13 - © ESAB AB 2017...
  • Page 14: Operation

    Orange indicating lamp, overheating 13 Connection BLUE for cooling water to the wire feed unit Digital instrument V/A* NOTE! *Digital instrument V/A only available on certain models. 0349 301 124 - 14 - © ESAB AB 2017...
  • Page 15: Overheating Protection

    A thermal overload cutout protects against overheating. The cutout resets automatically when the unit has cooled. Inductance connection Higher inductance produces a more flowing weld and fewer spatters. Lower inductance produces a harsher sound and a stable, concentrated arc. 0349 301 124 - 15 - © ESAB AB 2017...
  • Page 16: Maintenance

    Otherwise the air inlet/outlet may become blocked and cause overheating. To avoid this you can use an air filter. Topping up the coolant ESAB ready mixed coolant is recommended for use. See "ACCESSORIES" chapter. • Fill with coolant. (The fluid level must not exceed the upper marking but neither must it be below the lower marking).
  • Page 17 6 MAINTENANCE CAUTION! The coolant must be handled as chemical waste. 0349 301 124 - 17 - © ESAB AB 2017...
  • Page 18: Troubleshooting

    • Check that the welding current supply and return cables are correctly connected. • Check that the correct current value is set. • Check that the correct welding wires are being used. • Check the main power supply fuses. 0349 301 124 - 18 - © ESAB AB 2017...
  • Page 19: Ordering Spare Parts

    Spare parts and wear parts can be ordered through your nearest ESAB dealer, see the back cover of this document. When ordering, please state product type, serial number, designation and spare part number in accordance with the spare parts list.
  • Page 20: Cleaning

    CLEANING CLEANING 0349 301 124 - 20 - © ESAB AB 2017...
  • Page 21: Diagram

    DIAGRAM DIAGRAM Origo Mig L305, 400-415 V 0349 301 124 - 21 - © ESAB AB 2017...
  • Page 22 DIAGRAM Origo Mig L405, 400-415 V 0349 301 124 - 22 - © ESAB AB 2017...
  • Page 23 DIAGRAM Origo Mig L405, 230-500 V 0349 301 124 - 23 - © ESAB AB 2017...
  • Page 24: Ordering Numbers

    0349 306 595 Origo™ Mig L405w 230/400-415/500 V 3~ 50 Hz; 230/440-460 V 3~ 60 Hz 0349 313 090 Origo™ Mig L405 400-415 V 3~ 50 Hz with digital instrument Technical documentation is available on the Internet at: www.esab.com 0349 301 124 - 24 - © ESAB AB 2017...
  • Page 25: Accessories

    0459 495 882 Origo Feed L304, open 0349 302 451 Digital meter (L405) 0349 302 598 Digital meter (L305) 0349 302 250 Transformer kit for CO heater 0349 303 362 Cable holder 0349 301 124 - 25 - © ESAB AB 2017...
  • Page 26 0349 309 471 Fan speed reductor (L405) 0465 720 002 ESAB ready mixed coolant (10 l / 2.64 gal) Use of any other cooling liquid than the prescribed one might damage the equipment. In case of such damage, all warranty undertakings from ESAB cease to apply.
  • Page 27 ACCESSORIES 0349 301 124 - 27 - © ESAB AB 2017...
  • Page 28 ESAB subsidiaries and representative offices Europe THE NETHERLANDS North and South America SOUTH KOREA ESAB Nederland B.V. ESAB SeAH Corporation AUSTRIA Amersfoort ARGENTINA Kyungnam ESAB Ges.m.b.H Tel: +31 33 422 35 55 CONARCO Tel: +82 55 269 8170 Vienna-Liesing Fax: +31 33 422 35 44...

This manual is also suitable for: