HearthStone Aurora 8900 Series Owner's Manual page 13

Table of Contents

Advertisement

Hearthstone Quality Home Heating Products, Inc
Venting Chart Worksheet Examples
A. Fuel:
B. Total Vertical Vent Rise:
C. Total Horiz. Vent Run (Actual):
D. 90° Elbows Needed:
E. 45° Elbows Needed:
F. Total 90° Elbows Equivalent :
G. 90° Elbows in Excess of 2:
H. Additional Horiz. Feet Equivalent
I. Total Horizontal Vent Run (Equivalent):
Use Natural Gas Chart Settings for:
0 feet Vertical Rise, 0 feet Horizontal Run.
Exhaust Restrictor Used:
Air Restrictor Tabs Open:
A. Fuel:
B. Total Vertical Vent Rise:
C. Total Horiz. Vent Run (Actual):
D. 90° Elbows Needed:
E. 45° Elbows Needed:
F. Total 90° Elbows Equivalent :
G. 90° Elbows in Excess of 2:
H. Additional Horiz. Feet Equivalent
I. Total Horizontal Vent Run (Equivalent):
Use Natural Gas Chart Settings for:
12 feet Vertical Rise, 0 feet Horizontal Run.
Exhaust Restrictor Used:
Air Restrictor Tabs Open:
A. Fuel:
B. Total Vertical Vent Rise:
C. Total Horizontal Vent Run (Actual):
D. 90° Elbows Needed:
E. 45° Elbows Needed:
F. Total 90° Elbows Equivalent:
G. 90° Elbows in Excess of 2:
H. Additional Horiz. Feet Equivalent:
I. Total Horiz. Vent Run (Equivalent)
Use Natural Gas Chart Settings for:
6 feet Vertical Rise, 9 feet Horizontal Run.
Exhaust Restrictor Required:
Air Restrictor Tabs Open:
Natural Gas
0 feet
0 feet
0
0
0
0
0
0
Restrictor Not Used
Restrictor Not Used
Natural Gas
12 feet
0 feet
1
0
0
0
0
0
B
Restrictor Not Used
Natural Gas
6 feet
6 feet
3
0
3+(0 x ½) = 3
3 - 2 = 1
1 X 3 = 3
6 + 3 = 9
B
Restrictor Not Used
A. Fuel:
B. Total Vertical Vent Rise:
C. Total Horizontal Vent Run (Actual):
D. 90° Elbows Needed:
E. 45° Elbows Needed:
F. F. Total 90° Elbows Equivalent:
G. 90° Elbows in Excess of 2:
H. Additional Horiz. Feet Equivalent:
I. Total Horiz. Vent Run (Equivalent):
Use LP Gas Chart Settings for:
1 feet Vertical Rise, 3 feet Horizontal Run.
Exhaust Restrictor Used:
Air Restrictor Tabs Open:
A. Fuel:
B. Total Vertical Vent Rise:
C. Total Horizontal Vent Run (Actual):
D. 90° Elbows Needed:
E. 45° Elbows Needed:
F. F. Total 90° Elbows Equivalent:
G. 90° Elbows in Excess of 2:
H. Additional Horiz. Feet Equivalent:
I. Total Horiz. Vent Run (Equivalent):
Use LP Gas Chart Settings for:
10 feet Vertical Rise, 10 feet Horizontal Run.
Exhaust Restrictor Required:
Air Restrictor Tabs Open:
A. Fuel:
B. Total Vertical Vent Rise:
C. Total Horizontal Vent Run (Actual):
D. 90° Elbows Needed:
E. 45° Elbows Needed:
F. Total 90° Elbows Equivalent:
G. 90° Elbows in Excess of 2:
H. Additional Horiz. Feet Equivalent:
I. Total Horiz.Vent Run (Equivalent):
Use LP Gas Chart Settings for:
2 feet Vertical Rise, 10 feet Horizontal Run.
Exhaust Restrictor Used:
Air Restrictor Tabs Open:
ORION 16 Series 8900
LP Gas
1 feet
3 feet
2
0
2+(0 x ½) = 2
2 - 2 = 0
0 x 3 = 0
3 + 0 = 3
Restrictor Not Used
Restrictor Not Used
LP Gas
10 feet
7 feet
2
2
2+(2 x ½) = 3
3 - 2 = 1
1 x 3 = 3
7 + 3 = 10
B
3
LP Gas
2 feet
10 feet
2
0
2+(0 x ½) = 2
2 - 2 = 0
0 x 3 = 0
10 + 0 = 10
A
Restrictor Not Used
13