6.5.4 BBR16 power limitation

6.5.5 Smart Grid capacity limitation due to buffering

ERRA08~12E + ELVZ12S18+23E
Daikin Altherma 3 R MT F
4P708478-1 – 2023.05
INFORMATION
Restriction: BBR16 settings are only visible when the language of the user interface is
set to Swedish.
NOTICE
2 weeks to change. After you activated BBR16, you only have 2 weeks to change its
settings (BBR16 activation and BBR16 power limit). After 2 weeks, the unit
freezes these settings.
Note: This is different from the permanent power limitation, which is always
changeable.
Use the BBR16 power limitation when you must comply with BBR16 regulations
(Swedish energy regulations).
You can combine the BBR16 power limitation with the other kW power
consumption controls. If you do so, the unit uses the most restrictive control.
P
i
a
BBR16
P
Power input
i
t Time
BBR16 BBR16 limit level
a Power limitation active
b Actual power input
Setup and configuration
No additional equipment needed.
Set the power consumption control settings in [9.9] via the user interface (see
"Power consumption
-
Activate BBR16
-
Set the desired power limitation level
Smart Grid limitation for buffering is only possible if a Smart Grid is installed and
Recommended on mode is active.
You can combine Recommended on mode capacity limitation with other power
consumption controls. If you do so, the unit uses the most restrictive control.
INFORMATION
In case Smart Grid Forced off mode is active, the outdoor unit compressor and
electrical heaters will NOT operate.
Setup and configuration
See
"9.3.10  To connect a Smart
4
supply" [
 221].
b
t
4
control" [
 224]):
Grid"  [
4
6
Application guidelines
|
  135] and
"Benefit kWh power
Installer reference guide
49