Daikin Altherma 3 R MT F Series Installer's Reference Manual page 117

Table of Contents

Advertisement

ERRA08~12E + ELVZ12S18+23E
Daikin Altherma 3 R MT F
4P708478-1 – 2023.05
b
L1
3N~,
50 Hz,
L2
400 V AC
L3
N
a Power supply cable (field supply)
b Field wiring
F1B Overcurrent fuse (field supply). Recommended fuse: 4 pole, 16 A or 20 A fuse, C
curve.
Q1DI Earth leakage circuit breaker (30 mA)(field supply)
2 Interconnection cable (indoor↔outdoor):
▪ Route the cable through the frame.
▪ Connect the wires to the terminal block (make sure the numbers match with
the numbers on the indoor unit) and the earth screw.
▪ Fix the cable with a cable tie.
Wires: (3+GND)×1.5 mm²
F1B
Q1DI
BRN
2
1
GRY
4
3
BLK
6
5
BLU
8
7
YLW/GRN
9
Electrical installation
|
a
Installer reference guide
117