Daikin EBBH11DF9W User Reference Manual
Hide thumbs Also See for EBBH11DF9W:
Table of Contents

Advertisement

Quick Links

EBBH11DF6V
EBBH11DF9W
EBBH16DF6V
EBBH16DF9W
EBBX11DF6V
EBBX11DF9W
EBBX16DF6V
EBBX16DF9W
User reference guide
Daikin Altherma 3 R F+W
EBVH11S18+23DJ6V
EBVH11S18+23DJ9W
EBVH16S18+23DJ6V
EBVH16S18+23DJ9W
EBVH16SU23DJ6V
EBVX11S18+23DJ6V
EBVX11S18+23DJ9W
EBVX16S18+23DJ6V
EBVX16S18+23DJ9W

Advertisement

Table of Contents
loading

Summary of Contents for Daikin EBBH11DF9W

  • Page 1 User reference guide Daikin Altherma 3 R F+W EBBH11DF6V EBVH11S18+23DJ6V EBBH11DF9W EBVH11S18+23DJ9W EBBH16DF6V EBVH16S18+23DJ6V EBBH16DF9W EBVH16S18+23DJ9W EBVH16SU23DJ6V EBBX11DF6V EBBX11DF9W EBVX11S18+23DJ6V EBBX16DF6V EBVX11S18+23DJ9W EBBX16DF9W EBVX16S18+23DJ6V EBVX16S18+23DJ9W...
  • Page 2: Table Of Contents

    Symptom: You are feeling too cold (hot) in your living room..................57 Symptom: The water at the tap is too cold........................57 Symptom: Heat pump failure ............................58 User reference guide EBBH/X11+16DF + EBVH/X11+16S(U)18+23DJ Daikin Altherma 3 R F+W 4P643607-1 – 2021.09...
  • Page 3 Overview: Relocation ..............................60 10 Disposal 11 Glossary 12 Installer settings: Tables to be filled in by installer 12.1 Configuration wizard............................... 63 12.2 Settings menu ................................. 64 EBBH/X11+16DF + EBVH/X11+16S(U)18+23DJ User reference guide Daikin Altherma 3 R F+W 4P643607-1 – 2021.09...
  • Page 4: About This Document

    Format: Paper (in the box of the indoor unit) + Digital files on http:// www.daikineurope.com/support-and-manuals/product-information/ Latest revisions of the supplied documentation may be available on the regional Daikin website or via your installer. The original documentation is written in English. All other languages are translations. EBBH/X11+16DF + EBVH/X11+16S(U)18+23DJ...
  • Page 5: Meaning Of Warnings And Symbols

    About this document Daikin Residential Controller app If set up by your installer, you can use the Daikin Residential Controller app to control and monitor the status of your system. For more information, see: http://www.onlinecontroller.daikineurope.com/ Breadcrumbs Breadcrumbs (example: [4.3]) help you to locate where you are in the menu structure of the user interface.
  • Page 6 Example: " 1–3 Figure title" means "Figure 3 in chapter 1". Indicates a table title or a reference to it. Example: " 1–3 Table title" means "Table 3 in chapter 1". EBBH/X11+16DF + EBVH/X11+16S(U)18+23DJ User reference guide Daikin Altherma 3 R F+W 4P643607-1 – 2021.09...
  • Page 7: User Safety Instructions

    Do NOT place any objects containing water on the unit. CAUTION ▪ Do NOT place any objects or equipment on top of the unit. ▪ Do NOT sit, climb or stand on the unit. EBBH/X11+16DF + EBVH/X11+16S(U)18+23DJ User reference guide Daikin Altherma 3 R F+W 4P643607-1 – 2021.09...
  • Page 8: Instructions For Safe Operation

    Do NOT use cleaning materials or means to accelerate the defrosting process other than those recommended by the manufacturer. ▪ Be aware that the refrigerant inside the system is odourless. EBBH/X11+16DF + EBVH/X11+16S(U)18+23DJ User reference guide Daikin Altherma 3 R F+W 4P643607-1 – 2021.09...
  • Page 9 Reason: Refrigerant might leak into the water circuit, and subsequently into the room when you purge air from the heat emitters or collectors. EBBH/X11+16DF + EBVH/X11+16S(U)18+23DJ User reference guide Daikin Altherma 3 R F+W 4P643607-1 – 2021.09...
  • Page 10: About The System

    Radiators, heat pump convectors, or fan coil units INFORMATION The indoor unit and the domestic hot water tank (if installed) can be separated or integrated depending on the indoor unit type. EBBH/X11+16DF + EBVH/X11+16S(U)18+23DJ User reference guide Daikin Altherma 3 R F+W 4P643607-1 – 2021.09...
  • Page 11: Quick Guide

    –if enabled– can still activate. However, for leaving water temperature control and external room thermostat control, the protection is NOT guaranteed. EBBH/X11+16DF + EBVH/X11+16S(U)18+23DJ User reference guide Daikin Altherma 3 R F+W 4P643607-1 – 2021.09...
  • Page 12 You can use the leaving water temperature setpoint screen to read out and adjust the desired leaving water temperature. 1 Go to [2]: Main zone or [3]: Additional zone. Main zone Additional zone EBBH/X11+16DF + EBVH/X11+16S(U)18+23DJ User reference guide Daikin Altherma 3 R F+W 4P643607-1 – 2021.09...
  • Page 13 X2. X1, X2 Outdoor ambient temperature Y1~Y4 Desired leaving water temperature a WD curve before changes b WD curve after changes c Slope d Offset EBBH/X11+16DF + EBVH/X11+16S(U)18+23DJ User reference guide Daikin Altherma 3 R F+W 4P643607-1 – 2021.09...
  • Page 14 For more information, see also: ▪ "5.4 Turning operation ON or OFF" [  24] ▪ "5.6 Space heating/cooling control" [  26] ▪ "5.8 Preset values and schedules" [  34] ▪ "5.9 Weather-dependent curve" [  44] EBBH/X11+16DF + EBVH/X11+16S(U)18+23DJ User reference guide Daikin Altherma 3 R F+W 4P643607-1 – 2021.09...
  • Page 15: Domestic Hot Water

    More information For more information, see also: ▪ "5.4 Turning operation ON or OFF" [  24] ▪ "5.7 Domestic hot water control" [  30] ▪ "5.8 Preset values and schedules" [  34] EBBH/X11+16DF + EBVH/X11+16S(U)18+23DJ User reference guide Daikin Altherma 3 R F+W 4P643607-1 – 2021.09...
  • Page 16: Operation

    The LCD screen has a sleeping function. After 15  min of non-interaction with the user interface, the screen darkens. Pressing any button or rotating any dial awakens the display. Dials and buttons You use the dials and buttons: EBBH/X11+16DF + EBVH/X11+16S(U)18+23DJ User reference guide Daikin Altherma 3 R F+W 4P643607-1 – 2021.09...
  • Page 17 : Turn the right dial. Navigate through the possible values and settings. ▪ : Press the right dial. Confirm your choice and go to the next menu item. EBBH/X11+16DF + EBVH/X11+16S(U)18+23DJ User reference guide Daikin Altherma 3 R F+W 4P643607-1 – 2021.09...
  • Page 18: Menu Structure: Overview User Settings

    (**) Only accessible by installer (***) Only applicable when WLAN is installed INFORMATION Depending on the selected installer settings and unit type, settings will be visible/ invisible. EBBH/X11+16DF + EBVH/X11+16S(U)18+23DJ User reference guide Daikin Altherma 3 R F+W 4P643607-1 – 2021.09...
  • Page 19: Possible Screens: Overview

    26 Feb 2019 22:19 Possible actions on this screen Go through the list of the main menu. Go to the main menu screen. Enable/disable breadcrumbs. EBBH/X11+16DF + EBVH/X11+16S(U)18+23DJ User reference guide Daikin Altherma 3 R F+W 4P643607-1 – 2021.09...
  • Page 20 Outdoor unit Indoor unit / domestic hot water tank Floor-standing indoor unit with integrated tank Wall-mounted indoor unit Wall-mounted indoor unit with separated tank Water pressure EBBH/X11+16DF + EBVH/X11+16S(U)18+23DJ User reference guide Daikin Altherma 3 R F+W 4P643607-1 – 2021.09...
  • Page 21 "8.1 To display the help text in case of a malfunction" [  56] for more information. If the corresponding operation (for example: space heating) is not active, the circle is greyed out. EBBH/X11+16DF + EBVH/X11+16S(U)18+23DJ User reference guide Daikin Altherma 3 R F+W 4P643607-1 – 2021.09...
  • Page 22: Main Menu Screen

    User settings mode and quiet mode. Displays data and information about the Information indoor unit. Installer settings Restriction: Only for the installer. Gives access to advanced settings. EBBH/X11+16DF + EBVH/X11+16S(U)18+23DJ User reference guide Daikin Altherma 3 R F+W 4P643607-1 – 2021.09...
  • Page 23: Setpoint Screen

    Restriction: Only displayed if a wireless LAN Wireless gateway (WLAN) is installed. Contains settings needed when configuring the Daikin Residential Controller app. 5.3.3 Setpoint screen The setpoint screen is displayed for screens describing system components that need a setpoint value.
  • Page 24: Detailed Screen With Values

    Space heating/cooling operation a Space heating/cooling operation ON b Space heating/cooling operation OFF EBBH/X11+16DF + EBVH/X11+16S(U)18+23DJ User reference guide Daikin Altherma 3 R F+W 4P643607-1 – 2021.09...
  • Page 25: To Turn On Or Off

    1 Go to [C.3]: Operation > Tank. Operation Space heating/cooling Tank 2 Set operation to On or Off. 5.5 Reading out information To read out information 1 Go to [8]: Information. EBBH/X11+16DF + EBVH/X11+16S(U)18+23DJ User reference guide Daikin Altherma 3 R F+W 4P643607-1 – 2021.09...
  • Page 26: Space Heating/Cooling Control

    You have to tell the system which operation mode to use. To determine if a heating/cooling heat pump model is installed 1 Go to [4]: Space heating/cooling. EBBH/X11+16DF + EBVH/X11+16S(U)18+23DJ User reference guide Daikin Altherma 3 R F+W 4P643607-1 – 2021.09...
  • Page 27 ▪ Cooling only: Restricted 4 Confirm the changes. Example: Changeover restrictions When Restriction During cold season. Heating only Example: October, November, December, January, February and March. EBBH/X11+16DF + EBVH/X11+16S(U)18+23DJ User reference guide Daikin Altherma 3 R F+W 4P643607-1 – 2021.09...
  • Page 28: Determining Which Temperature Control You Are Using

    During room temperature control, you can use the room temperature setpoint screen to read out and adjust the desired room temperature. 1 Go to [1]: Room. Room EBBH/X11+16DF + EBVH/X11+16S(U)18+23DJ User reference guide Daikin Altherma 3 R F+W 4P643607-1 – 2021.09...
  • Page 29: To Change The Desired Leaving Water Temperature

    You can use the leaving water temperature setpoint screen to read out and adjust the desired leaving water temperature. 1 Go to [2]: Main zone or [3]: Additional zone. Main zone Additional zone EBBH/X11+16DF + EBVH/X11+16S(U)18+23DJ User reference guide Daikin Altherma 3 R F+W 4P643607-1 – 2021.09...
  • Page 30: Domestic Hot Water Control

    4 hours starting from the scheduled start-up of disinfection. If the booster heater is restricted during disinfection, this function will NOT be successful and the applicable warning AH will be generated. EBBH/X11+16DF + EBVH/X11+16S(U)18+23DJ User reference guide Daikin Altherma 3 R F+W 4P643607-1 – 2021.09...
  • Page 31: Reheat Mode

    In reheat mode the DHW tank continuously heats up to the temperature shown on the home screen (example: 50°C) when the temperature drops below a certain value. 60°C 50°C 40°C 15°C 00:00 07:00 14:00 21:00 DHW tank temperature t Time EBBH/X11+16DF + EBVH/X11+16S(U)18+23DJ User reference guide Daikin Altherma 3 R F+W 4P643607-1 – 2021.09...
  • Page 32: Scheduled Mode

    (example: 45°C). This ensures that a minimum amount of hot water is available at all times. Example: EBBH/X11+16DF + EBVH/X11+16S(U)18+23DJ User reference guide Daikin Altherma 3 R F+W 4P643607-1 – 2021.09...
  • Page 33: To Change The Domestic Hot Water Temperature

    Activate or deactivate Powerful operation as follows: 1 Go to [5.1]: Tank > Powerful operation 2 Turn powerful operation Off or On. EBBH/X11+16DF + EBVH/X11+16S(U)18+23DJ User reference guide Daikin Altherma 3 R F+W 4P643607-1 – 2021.09...
  • Page 34: Preset Values And Schedules

    Bivalent is enabled by the installer. Additional to the user-defined preset values, the system also contains some system-defined preset values that you can use when programming schedules. EBBH/X11+16DF + EBVH/X11+16S(U)18+23DJ User reference guide Daikin Altherma 3 R F+W 4P643607-1 – 2021.09...
  • Page 35: Using And Programming Schedules

    User defined 1 3 Select Select. Delete Rename Select 4 Select the schedule that you currently want to use. Possible schedules The table contains the following information: EBBH/X11+16DF + EBVH/X11+16S(U)18+23DJ User reference guide Daikin Altherma 3 R F+W 4P643607-1 – 2021.09...
  • Page 36 Off: When the system is NOT allowed to heat additional zone in heating up the additional zone. mode. ▪ On: When the system is allowed to heat up the additional zone. EBBH/X11+16DF + EBVH/X11+16S(U)18+23DJ User reference guide Daikin Altherma 3 R F+W 4P643607-1 – 2021.09...
  • Page 37 Possible actions: You can use the following system-defined preset values: ▪ Quiet ▪ More quiet ▪ Most quiet "About quiet mode" [  50]. EBBH/X11+16DF + EBVH/X11+16S(U)18+23DJ User reference guide Daikin Altherma 3 R F+W 4P643607-1 – 2021.09...
  • Page 38: Schedule Screen: Example

    5 Program the schedule for Saturday and copy it to Sunday. 6 Give the schedule a name. To go to the schedule 1 Go to [1.1]: Room > Schedule. 2 Set scheduling to Yes. EBBH/X11+16DF + EBVH/X11+16S(U)18+23DJ User reference guide Daikin Altherma 3 R F+W 4P643607-1 – 2021.09...
  • Page 39 Delete Edit Copy 3 Select OK to confirm. To program the schedule for Monday 1 Select Monday. User defined 1 2 Select Edit. Delete Edit Copy EBBH/X11+16DF + EBVH/X11+16S(U)18+23DJ User reference guide Daikin Altherma 3 R F+W 4P643607-1 – 2021.09...
  • Page 40 1 Select Monday. User defined 1 2 Select Copy. Delete Edit Copy Result: Next to the copied day, "C" is displayed. 3 Select Tuesday. User defined 1 EBBH/X11+16DF + EBVH/X11+16S(U)18+23DJ User reference guide Daikin Altherma 3 R F+W 4P643607-1 – 2021.09...
  • Page 41 8:00 21°C 23:00 18°C --:-- 4 Confirm the changes. 5 Select Saturday. 6 Select Copy. 7 Select Sunday. 8 Select Paste. Result: User defined 1 EBBH/X11+16DF + EBVH/X11+16S(U)18+23DJ User reference guide Daikin Altherma 3 R F+W 4P643607-1 – 2021.09...
  • Page 42: Setting The Energy Prices

    Electricity: 12 euro cents/kWh [7.5.1]=12 To set the gas price 1 Go to [7.6]: User settings > Gas price. 2 Select the correct gas price. 3 Confirm the changes. EBBH/X11+16DF + EBVH/X11+16S(U)18+23DJ User reference guide Daikin Altherma 3 R F+W 4P643607-1 – 2021.09...
  • Page 43 To set the electricity price in case of an incentive per kWh renewable energy Calculate the value for the electricity price with following formula: ▪ Actual electricity price+Incentive/kWh EBBH/X11+16DF + EBVH/X11+16S(U)18+23DJ User reference guide Daikin Altherma 3 R F+W 4P643607-1 – 2021.09...
  • Page 44: Weather-Dependent Curve

    EBBH/X11+16DF + EBVH/X11+16S(U)18+23DJ User reference guide Daikin Altherma 3 R F+W 4P643607-1 – 2021.09...
  • Page 45: 2-Points Curve

    See "5.9.4 Using weather-dependent curves" [  47]. 5.9.2 2-points curve Define the weather-dependent curve with these two setpoints: ▪ Setpoint (X1, Y2) ▪ Setpoint (X2, Y1) Example EBBH/X11+16DF + EBVH/X11+16S(U)18+23DJ User reference guide Daikin Altherma 3 R F+W 4P643607-1 – 2021.09...
  • Page 46: Slope-Offset Curve

    Examples Weather-dependent curve when slope is selected: Weather-dependent curve when offset is selected: EBBH/X11+16DF + EBVH/X11+16S(U)18+23DJ User reference guide Daikin Altherma 3 R F+W 4P643607-1 – 2021.09...
  • Page 47: Using Weather-Dependent Curves

    5.9.4 Using weather-dependent curves Configure weather-dependent curves as following: To define the setpoint mode To use the weather-dependent curve, you need to define the correct setpoint mode: EBBH/X11+16DF + EBVH/X11+16S(U)18+23DJ User reference guide Daikin Altherma 3 R F+W 4P643607-1 – 2021.09...
  • Page 48 You cannot configure the curve with temperatures that are higher or lower than the set maximum and minimum setpoints for that zone or for the tank. When the maximum or minimum setpoint is reached, the curve flattens out. EBBH/X11+16DF + EBVH/X11+16S(U)18+23DJ User reference guide Daikin Altherma 3 R F+W 4P643607-1 – 2021.09...
  • Page 49: Other Functionalities

    ↑ ↓ ↓ ↓ ↓ ↓ "5.9.2 2-points curve" [  45]. 5.10 Other functionalities 5.10.1 To configure time and date 1 Go to [7.2] User settings > Time/date. EBBH/X11+16DF + EBVH/X11+16S(U)18+23DJ User reference guide Daikin Altherma 3 R F+W 4P643607-1 – 2021.09...
  • Page 50: Using Quiet Mode

    Setting the starting date and ending date of your holiday. Activating the holiday mode. To check if holiday mode is activated and/or running is displayed on the home screen, holiday mode is active. EBBH/X11+16DF + EBVH/X11+16S(U)18+23DJ User reference guide Daikin Altherma 3 R F+W 4P643607-1 – 2021.09...
  • Page 51: Using Wlan

    About the WLAN cartridge or WLAN module The WLAN cartridge or WLAN module (only one of the two needed) connects the system to the internet. As user you can then control the system via the Daikin Residential Controller app. This needs the following components in case of WLAN cartridge:...
  • Page 52 The Daikin Residential Controller app needs to be installed on the user's smartphone. See: http://www.onlinecontroller.daikineurope.com/ Configuration To configure the Daikin Residential Controller app, follow the in-app instructions. While doing this, the following actions and information are needed on the user interface: [D] Wireless gateway...
  • Page 53 [D.6] Cloud connection: Read out the status of the connection to the cloud: 1 Go to [D.6]: Wireless gateway > Cloud connection. 2 Read out the connection status: ▪ Not connected ▪ Connected EBBH/X11+16DF + EBVH/X11+16S(U)18+23DJ User reference guide Daikin Altherma 3 R F+W 4P643607-1 – 2021.09...
  • Page 54: Energy Saving Tips

    Program to turn ON the domestic hot water pump ONLY during periods of the day when instant hot water is necessary. Example: In the morning and evening. EBBH/X11+16DF + EBVH/X11+16S(U)18+23DJ User reference guide Daikin Altherma 3 R F+W 4P643607-1 – 2021.09...
  • Page 55: Maintenance And Service

    Do NOT use the unit until a service person confirms that the part from which the refrigerant leaked has been repaired. EBBH/X11+16DF + EBVH/X11+16S(U)18+23DJ User reference guide Daikin Altherma 3 R F+W 4P643607-1 – 2021.09...
  • Page 56: Troubleshooting

    Conditions: The user permission level is set to advanced end user. 1 Go to [8.2]: Information > Malfunction history. You see a list of the most recent malfunctions. EBBH/X11+16DF + EBVH/X11+16S(U)18+23DJ User reference guide Daikin Altherma 3 R F+W 4P643607-1 – 2021.09...
  • Page 57: Symptom: You Are Feeling Too Cold (Hot) In Your Living Room

    DHW tank to a preset value (Eco setpoint = lower tank temperature) during the day. "5.8.2  Using programming schedules"  [   35] and "5.8.3  Schedule screen: Example" [  38]. EBBH/X11+16DF + EBVH/X11+16S(U)18+23DJ User reference guide Daikin Altherma 3 R F+W 4P643607-1 – 2021.09...
  • Page 58: Symptom: Heat Pump Failure

    Perform hydraulic balancing to assure that the flow is correctly distributed between the emitters. hydraulic balancing sufficient, change pump limitation settings ([9-0D] and [9-0E] if applicable). EBBH/X11+16DF + EBVH/X11+16S(U)18+23DJ User reference guide Daikin Altherma 3 R F+W 4P643607-1 – 2021.09...
  • Page 59 If yes, make sure that the room where you want to purge air is sufficiently ventilated. Reason: Refrigerant might leak into the water circuit, and subsequently into the room when you purge air from the heat emitters or collectors. EBBH/X11+16DF + EBVH/X11+16S(U)18+23DJ User reference guide Daikin Altherma 3 R F+W 4P643607-1 – 2021.09...
  • Page 60: Relocation

    If you want to relocate parts of your system, contact your installer. You can find the contact/helpdesk number via the user interface. 1 Go to [8.3]: Information > Dealer information. EBBH/X11+16DF + EBVH/X11+16S(U)18+23DJ User reference guide Daikin Altherma 3 R F+W 4P643607-1 – 2021.09...
  • Page 61: Disposal

    Do NOT try to dismantle the system yourself: dismantling of the system, treatment of the refrigerant, oil and other parts MUST comply with applicable legislation. Units MUST be treated at a specialised treatment facility for reuse, recycling and recovery. EBBH/X11+16DF + EBVH/X11+16S(U)18+23DJ User reference guide Daikin Altherma 3 R F+W 4P643607-1 – 2021.09...
  • Page 62: Glossary

    Optional equipment Equipment made or approved by Daikin that can be combined with the product according to the instructions in the accompanying documentation. Field supply Equipment NOT made by Daikin that can be combined with the product according to the instructions in the accompanying documentation.
  • Page 63: Installer Settings: Tables To Be Filled In By Installer

    Additional zone (only if [4.4]=1, dual zone) Emitter type [3.7] Control (read only) [3.9] Setpoint mode [3.4] Schedule [3.1] WD curve type [3.C] (read only) Tank (if applicable) EBBH/X11+16DF + EBVH/X11+16S(U)18+23DJ User reference guide Daikin Altherma 3 R F+W 4P643607-1 – 2021.09...
  • Page 64: Settings Menu

    WD curve type [5.E] (read only) 12.2 Settings menu Setting Fill in… Main zone Thermostat type [2.A] Additional zone (if applicable) Thermostat type [3.A] Information Dealer information [8.3] EBBH/X11+16DF + EBVH/X11+16S(U)18+23DJ User reference guide Daikin Altherma 3 R F+W 4P643607-1 – 2021.09...
  • Page 68 4P643607-1 2021.09 Verantwortung für Energie und Umwelt...

Table of Contents