11.3.4 Menu screen

ERRA08~12E + ELVZ12S18+23E
Daikin Altherma 3 R MT F
4P708478-1 – 2023.05
Submenu
[1]
Room
[2]
Main zone
[3]
Additional zone
[4]
Space heating/
cooling
[5]
Tank
[7]
User settings
[8]
Information
[9]
Installer settings Restriction: Only for the installer.
[A]
Commissioning
[B]
User profile
[C]
Operation
[D]
Wireless gateway
Description
Restriction: Only displayed if a dedicated
Human Comfort Interface (BRC1HHDA used as
room thermostat) is controlling the indoor
unit.
Set the room temperature.
Shows the applicable symbol for your main
zone emitter type.
Set the leaving water temperature for the
main zone.
Restriction: Only displayed if there are two
leaving water temperature zones. Shows the
applicable symbol for your additional zone
emitter type.
Set the leaving water temperature for the
additional zone (if present).
Shows the applicable symbol of your unit.
Put the unit in heating mode or cooling mode.
You cannot change the mode on heating only
models.
Set the domestic hot water tank temperature.
Gives access to user settings such as holiday
mode and quiet mode.
Displays data and information about the
indoor unit.
Gives access to advanced settings.
Restriction: Only for the installer.
Perform tests and maintenance.
Change the active user profile.
Turn heating/cooling functionality and
domestic hot water preparation on or off.
Restriction: Only displayed if a wireless LAN
(WLAN) is installed.
Contains settings needed when configuring
the ONECTA app.
Example:
7.1
Language
Time/date
Holiday
11
Configuration
|
Installer reference guide