Daikin Altherma 3 R F+W Operation Manual

Daikin Altherma 3 R F+W Operation Manual

Hide thumbs Also See for Altherma 3 R F+W:

Advertisement

Operation manual
Daikin Altherma 3 R F+W
EHBH04E*6V
EHBH08E*6V
EHBH08E*9W
EHBX04E*6V
EHBX08E*6V
EHBX08E*9W
EHVH04S(U)18E*6V
EHVH04S(U)23E*6V
EHVH08S(U)18E*6V
EHVH08S(U)23E*6V
EHVH08S18E*9W
EHVH08S23E*9W
EHVX04S18E*3V
EHVX04S18E*6V
EHVX04S23E*3V
EHVX04S23E*6V
EHVX08S18E*6V
EHVX08S23E*6V
Operation manual
EHVX08S18E*9W
English
Daikin Altherma 3 R F+W
EHVX08S23E*9W

Advertisement

Table of Contents
loading

Summary of Contents for Daikin Altherma 3 R F+W

  • Page 1 Operation manual Daikin Altherma 3 R F+W EHBH04E*6V EHBH08E*6V EHBH08E*9W EHBX04E*6V EHBX08E*6V EHBX08E*9W EHVH04S(U)18E*6V EHVH04S(U)23E*6V EHVH08S(U)18E*6V EHVH08S(U)23E*6V EHVH08S18E*9W EHVH08S23E*9W EHVX04S18E*3V EHVX04S18E*6V EHVX04S23E*3V EHVX04S23E*6V EHVX08S18E*6V EHVX08S23E*6V Operation manual EHVX08S18E*9W English Daikin Altherma 3 R F+W EHVX08S23E*9W...
  • Page 2: Table Of Contents

    Detailed screen with values ........Latest revisions of the supplied documentation may be available on Turning operation ON or OFF ........... the regional Daikin website or via your installer. 4.3.1 Visual indication ............The original documentation is written in English. All other languages 4.3.2...
  • Page 3: General

    Do NOT use the unit until a service person confirms that the part from which the refrigerant leaked has been repaired. EHBH/X04+08EA/EJ6V+9W + EHVH/X04+08S(U)18+23EA/EJ3V Operation manual +6V+9W Daikin Altherma 3 R F+W 4P629084-2 – 2020.08...
  • Page 4: About The System

    Radiators, heat pump convectors, or fan coil units INFORMATION The indoor unit and the domestic hot water tank (if installed) can be separated or integrated depending on the indoor unit type. Operation manual EHBH/X04+08EA/EJ6V+9W + EHVH/X04+08S(U)18+23EA/EJ3V +6V+9W Daikin Altherma 3 R F+W 4P629084-2 – 2020.08...
  • Page 5: Possible Screens: Overview

    You see an overview of the unit configuration and the room and setpoint temperatures. Only symbols applicable for your configuration are visible on the home screen. EHBH/X04+08EA/EJ6V+9W + EHVH/X04+08S(U)18+23EA/EJ3V Operation manual +6V+9W Daikin Altherma 3 R F+W 4P629084-2 – 2020.08...
  • Page 6: Main Menu Screen

    [2] Main zone screen Space heating/cooling Selected submenu Possible actions on this screen °C °C Go through the list. – – Enter the submenu. Room Main zone Enable/disable breadcrumbs. Operation manual EHBH/X04+08EA/EJ6V+9W + EHVH/X04+08S(U)18+23EA/EJ3V +6V+9W Daikin Altherma 3 R F+W 4P629084-2 – 2020.08...
  • Page 7: Detailed Screen With Values

    –if enabled– will separately. If a functionality is disabled, the corresponding remain active. temperature icon in the home screen will be greyed out. EHBH/X04+08EA/EJ6V+9W + EHVH/X04+08S(U)18+23EA/EJ3V Operation manual +6V+9W Daikin Altherma 3 R F+W 4P629084-2 – 2020.08...
  • Page 8: Space Heating/Cooling Control

    Restricted per month according to the Operation mode schedule [4.2]. Operation manual EHBH/X04+08EA/EJ6V+9W + EHVH/X04+08S(U)18+23EA/EJ3V +6V+9W Daikin Altherma 3 R F+W 4P629084-2 – 2020.08...
  • Page 9: Domestic Hot Water Control

    Powerful operation allows the domestic hot water to be heated by the backup heater or booster heater. Use this mode on days when there is more hot water usage than usual. EHBH/X04+08EA/EJ6V+9W + EHVH/X04+08S(U)18+23EA/EJ3V Operation manual +6V+9W Daikin Altherma 3 R F+W 4P629084-2 – 2020.08...
  • Page 10: Advanced Usage

    1 Select the day of which you want to clear the content. For example Friday User defined 1 User pin code The User pin code is 0000. User 0000 Operation manual EHBH/X04+08EA/EJ6V+9W + EHVH/X04+08S(U)18+23EA/EJ3V +6V+9W Daikin Altherma 3 R F+W 4P629084-2 – 2020.08...
  • Page 11 1 Select Monday. 8 Select Paste. User defined 1 Result: User defined 1 2 Select Copy. Delete Edit Copy Result: Next to the copied day, "C" is displayed. EHBH/X04+08EA/EJ6V+9W + EHVH/X04+08S(U)18+23EA/EJ3V Operation manual +6V+9W Daikin Altherma 3 R F+W 4P629084-2 – 2020.08...
  • Page 12 The schedule name can contain up to 15 characters. 5 Confirm the new name. INFORMATION Not all schedules can be renamed. Operation manual EHBH/X04+08EA/EJ6V+9W + EHVH/X04+08S(U)18+23EA/EJ3V +6V+9W Daikin Altherma 3 R F+W 4P629084-2 – 2020.08...
  • Page 13: Menu Structure: Overview User Settings

    Only accessible by installer (***) Only applicable when WLAN adapter module is installed INFORMATION Depending on the selected installer settings and unit type, settings will be visible/invisible. EHBH/X04+08EA/EJ6V+9W + EHVH/X04+08S(U)18+23EA/EJ3V Operation manual +6V+9W Daikin Altherma 3 R F+W 4P629084-2 – 2020.08...
  • Page 14: Installer Settings: Tables To Be Filled In By Installer

    ▪ Do NOT increase/decrease the desired room temperature to speed up space heating/cooling. The space will NOT heat up/cool WARNING: FLAMMABLE MATERIAL down faster. The refrigerant inside this unit is mildly flammable. Operation manual EHBH/X04+08EA/EJ6V+9W + EHVH/X04+08S(U)18+23EA/EJ3V +6V+9W Daikin Altherma 3 R F+W 4P629084-2 – 2020.08...
  • Page 15: To Find The Contact/Helpdesk Number

    ▪ For EHBH/X: The backup heater will automatically take over the heat load, and the booster heater in the optional tank will automatically take over the domestic hot water production. EHBH/X04+08EA/EJ6V+9W + EHVH/X04+08S(U)18+23EA/EJ3V Operation manual +6V+9W Daikin Altherma 3 R F+W 4P629084-2 – 2020.08...
  • Page 16: Symptom: The System Is Making Gurgling Noises After Commissioning

    MUST be treated at a specialised treatment facility for reuse, recycling and recovery. Glossary DHW = Domestic hot water Hot water used, in any type of building, for domestic purposes. Operation manual EHBH/X04+08EA/EJ6V+9W + EHVH/X04+08S(U)18+23EA/EJ3V +6V+9W Daikin Altherma 3 R F+W 4P629084-2 – 2020.08...
  • Page 20 4P629084-2 0000000S 4P629084-2 2020.08 Verantwortung für Energie und Umwelt...

This manual is also suitable for:

Ehvx-e9wEhbx-e6vEhbh-e6v

Table of Contents