Field settings table
Breadcrumb Field code
Setting name
9.I
[9-01]
What is the mimimum desired LWT for main zone in heating?
9.I
[9-02]
What is the maximum desired LWT for main zone in cooling?
9.I
[9-03]
What is the mimimum desired LWT for main zone in cooling?
9.I
[9-04]
Leaving water temperature overshoot temperature.
9.I
[9-05]
What is the mimimum desired LWT for add. zone in heating?
9.I
[9-06]
What is the maximum desired LWT for add. zone in heating?
9.I
[9-07]
What is the mimimum desired LWT for add. zone in cooling?
9.I
[9-08]
What is the maximum desired LWT for add. zone in cooling?
9.I
[9-09]
What is the allowed LWT undershoot during cooling start-up?
9.I
[9-0A]
What is the room buffering temperature in heating?
9.I
[9-0B]
What is the room buffering temperature in cooling?
9.I
[9-0C]
Room temperature hysteresis.
9.I
[9-0D]
Pump speed limitation additional zone
9.I
[9-0E]
Pump speed limitation main zone
9.I
[C-00]
Domestic heating water priority.
9.I
[C-01]
--
9.I
[C-02]
Is an external backup heat source connected?
9.I
[C-03]
Bivalent activation temperature.
9.I
[C-04]
Bivalent hysteresis temperature.
9.I
[C-05]
What is the thermo request contact type for the main zone?
9.I
[C-06]
What is the thermo request contact type for the add. zone?
9.I
[C-07]
What is the unit control method in space operation?
9.I
[C-08]
Which type of external sensor is installed?
9.I
[C-09]
What is the required alarm output contact type?
9.I
[C-0A]
--
9.I
[C-0B]
--
9.I
[C-0C]
--
9.I
[C-0D]
--
9.I
[C-0E]
--
9.I
[D-00]
Which heaters are permitted if prefer. kWh rate PS is cut?
9.I
[D-01]
Contact type of preferential kWh rate PS installation?
9.I
[D-02]
Which type of DHW pump is installed?
9.I
[D-03]
Leaving water temperature compensation around 0°C.
9.I
[D-04]
Is a demand PCB connected?
9.I
[D-05]
Is the pump allowed to run if prefer. kWh rate PS is cut?
9.I
[D-07]
Is a solar kit connected?
(*1) *6V*_(*2) *9W*_
(*3) Only applicable for models where cooling is possible
Range, step
Default value
R/W
15~37°C, step: 1°C
25°C
R/W
18~22°C, step: 1°C
22°C (*3)
R/W
5~18°C, step: 1°C
7°C (*3)
R/W
1~4°C, step: 1°C
2°C
R/W
15~37°C, step: 1°C
25°C
R/W
37~65, step: 1°C
[2-0C]=2:
R/W
5~18°C, step: 1°C
7°C (*3)
R/W
18~22°C, step: 1°C
22°C (*3)
R/W
1~18°C, step: 1°C
18°C
R/W
[3-07]~[3-06]°C, step: 0,5°C
23°C
R/W
[3-09]~[3-08]°C, step: 0,5°C
23°C
R/W
1~6°C, step: 0,5°C
1°C
R/W
0~8, step:1
0: No limitation
1~4: 90~60% pump speed
5~8: 90~60% pump speed during
sampling
6
R/W
0~8, step:1
0: No limitation
R/O
0: Solar priority
0
R/W
0: No
1: Yes
R/W
-25~25°C, step: 1°C
0°C
R/W
2~10°C, step: 1°C
3°C
R/W
1: 1 contact
2: 2 contacts
R/W
0: -
1: 1 contact
2: 2 contacts
R/W
0: Leaving water
1: External room thermostat
2: Room thermostat
R/W
0: No
1: Outdoor
R/W
0: Abnormal
0
0
0
0
0
R/W
0: No
1: Only BSH
2: Only BUH
3: All
R/W
0: No
1: Open
2: Closed
3: Smart Grid
R/W
0: No DHW pump
1: Instant hot water
2: Disinfection
3: Circulation
4: Circulation and disinfection
R/W
0: No
1: increase 2°C, span 4°C
R/W
0: No
1: Pwr consmp ctrl
R/W
0: No
1: Yes
R/O
0: No
1: Yes (DHW)
2: Yes (DHW + SH)
11/12
Installer setting at variance with
default value
Date
Value
 4P717810‐1 ‐ 2022.11