Directed Electronics Viper 5501 Installation Manual page 55

Hide thumbs Also See for Viper 5501:
Table of Contents

Advertisement

3-9 Diesel Timer—Wait-To-Start Input
- Timed 15, 30, 45 SECONDS:
Default is the "Wait-to-Start" input control wire, or programmable to ignore the
input control wire by a delay of 15 (2), 30 (3), or 45(3) seconds. This feature
can also be optionally programmed with the Bitwriter®, with a delay from 1 to
90 seconds.
3-10 Accessory State During Wait-To-Start On:
This feature will allow the se-
lection of the accessory output to be ON or OFF during wait-to-start. Use the
two-honk setting for OFF.
3-11 2nd Status Output: Normal:
This feature will allow selection of status
output or a rear defogger mode that turns on ten seconds after the vehicle has
started if the vehicle interior temperature is below 55 degrees F. The defogger
mode has two selections, latched, the LED will flash twice, or pulsed, the LED will
flash three times. Latched mode will only stay on for 10 minutes.
Note: When the defogger mode is on, the output will always be active and can
be turned on independently with the remote for a one-time activation. (See the
Remote Functions table.)
3-12 Parking Lights Constant:
In the default setting, the parking lights (if connect-
ed) will come on solid during the remote start runtime. In the two - flash setting
the parking lights will flash during the remote start runtime. In the OFF setting, the
parking lights will not come ON or flash, when the vehicle is remote started.
3-13 Anti-Grind On:
With the anti-grind On (default) the ground-when-armed
output is active during remote start operation. This activates the optional starter
kill relay and prevents the customer from re-cranking the car with the key, when
doing key takeover. If accessories such as a voice module or window module
are added to the unit, it may be necessary to use the two-honk setting to pro-
gram this feature OFF.
3-14 Tach Mode Starter Release:
Normal: Use the two-honk setting to in-
crease time by 15% of the original tach programmed time. The LED will flash
twice (2). To decrease by 15% of the original programmed time, the LED will
flash three (3) times.
55
© 2008 Directed Electronics. All rights reserved.

Advertisement

Table of Contents