Charger safety
Battery not connected indication:
The charger is connected to the mains power
outlet: the status LED flashes green, the charger
is ready for a battery.
To attempt to wake up deeply discharged
batteries, the charger will apply short pulses.
Error indication:
Contact the nearest dealer in the following cases:
•
LED off ( ): the battery voltage is too high. Check the battery voltage;
•
2 flashes (
•
3 flashes (
connection;
•
4 flashes (
•
5 flashes (
condition or capacity;
•
6 flashes (
The INFACO lithium charger (ref.: AT180CC) is only for use with AT1000 Lithium
batteries (Ref: AT185BC). It is not suitable for other batteries.
): the battery is connected to the charger with an incorrect polarity;
): the charger output is short-circuited. Check the output cable
): the battery voltage is too low to be recharged safely;
): the safety timer has expired. Check the battery
): defective battery.