Refrigeration controller, type EET series

System protection

Table 11: System protection
Parameter name
System Protection
Voltage Protection function
Minimum Cut-in Voltage 110 V (230
V)
Minimum Cut out Voltage 110 V
(230 V)
Maximum cut out Voltage 110V
(230V)
Condenser Alarm Limit (°C)
Condenser Block Limit (°C)
Condenser OK Limit (°C)
Control sensor error handling type
Error Run Time (Mins)
Error Stop Time (Mins)
Zero Cross Config

Test Mode

Table 12: Test Mode
Parameter name
Test Mode
Operating mode

Service

Table 13: Service
Parameter name
Service
Parameter Version
Software Version
Code number
OEM low
OEM High
Thermostat cut in temperature (°C) CTi
Themostat cut out temperature (°C) CTO
Cabinet Air Temperature (°C)
Evaporator Temperature (°C)
Condenser Temperature (°C)
Door Status
Di Switch Status
Spindle position (%)
© Danfoss | Climate Solutions | 2023.07
Default
Code
Min.
Max.
value
SyP
uPt
No
No
Yes
uLi
100
70
230
uL0
95
70
225
uHi
260
110
270
CAL
80
0
120
CbL
85
0
120
CoL
60
0
120
EHd
Aut
no
Aut
Ert
0
0
60
Est
0
0
60
ZC
Yes
No
Yes
Default
Code
Min.
Max.
value
tst
tSt
Normal
Manual
Normal
Default
Code
Min.
Max.
value
Ser
Par
0
0
65535
Fir
0
65535
onL
0
65535
oEL
0
65535
oEH
0
65535
-100
200
-100
200
Cab
-100
200
Eva
-100
200
Con
-100
200
Dor
Open
Not con-
figured
Di1
Open
Not con-
figured
uSp
0
100
Description
This feature protects the compressor if the line voltage goes beyond the operating
range.
The lowest voltage at which the compressor is allowed to cut in.
If the voltage goes below this value when the compressor is running, the compres-
sor will be switched off. It is meant to avoid sudden switching on and off of com-
pressor due to voltage fluctuations. This cut-off voltage will override compressor
minimum run time.
When the compressor is running, it will be switched OFF if the voltage exceeds this
value. If the compressor is already stopped, it will remain switched off.
It sets the condenser temperature at which an alarm will be generated
It sets the compressor switched off due to high condenser temperature.
It sets the compressor to switch on again after it has been switched off due to high
condenser temperature, respecting minimum compressor stop time.
Method to control the cooling cycle in case of cabinet air sensor error:
"no" : no sensor error handling
"SEt" : follow configured error run and stop time.
"Aut" : control automatically based on past cycles time.
Cooling cycle ON time in case of cabinet sensor error (active only if EHd=Set)
Cooling cycle OFF time in case of cabinet sensor error (active only if EHd=Set)
It enhances the relay life and avoids relay sparks during relay ON and OFF. If "Yes" is
selected, the relays will be switched ON and OFF when the line-voltage is closeer to
zero.
Description
Normal mode - Normal operation mode of the controller
Manual mode- In this mode, output relays can be switched ON and OFF irrespective
of temperature conditions.
Description
OEM/Customer can use it to assign Parameter version
Software /Firmware version of the controller
Last four digits of the FG code number of the controller
OEM/customer can use it to assign their code number for their various applications
OEM/customer can use it to assign their code number for their various applications
Thermostat cut-in temperature at current spindle position
Thermostat cut-out temperature at current spindle position
Cabinet Air temperature
Evaporator Temp
Condenser Temp
Status of the door switch
Close: door is closed
Open: door is open
Not Configured: door switch is not configured
Status of Digital input:
Open: deactivated
Close: activated
Not Configured: Di switch not configured
Current position of the spindle
Warm - 0%
Cold -100%
BC320944106159en-000301 | 20