Danfoss EET Series User Manual page 27

Refrigeration controller
Table of Contents

Advertisement

Refrigeration controller, type EET series
Parameter name
Thermostat status
Defrost status (stages)
Defrost interval counter - Comp. run
time (Mins)
Defrost Interval counter - Elapsed
time (Mins)
Main Voltage
© Danfoss | Climate Solutions | 2023.07
Default
Code
Min.
Max.
value
thS
1
10
dES
1
4
InC
0
32767
Int
0
32767
uAC
1
300
Description
Controller operating status:
1: Initial state
2: Serving
3: Eco Mode
4: Initial Pull down (IPD)
5: Pull down /Super cool Mode
6: Emergency Mode
7: Main Switch Off
8: Holiday mode
9: Automatic Heater Control mode
10: Energy mode delay
1: Idle
2: Ice off
3: Drip off
4: Cooling Preperation
Defrost interval counter based on accumulated compressor runtime
Defrost interval counter based on elapsed time
Main power supply voltage
BC320944106159en-000301 | 27

Advertisement

Table of Contents
loading

Table of Contents