Danfoss EKE 347 Installation Manual

Danfoss EKE 347 Installation Manual

Liquid level controller
Hide thumbs Also See for EKE 347:

Advertisement

Quick Links

Installation guide
Liquid level controller
EKE 347
080G5000
1
Liquid Level Regulating principle
Danfoss
80G75_06-2014
3a
3c
© Danfoss A/S (RC-MDP/MWA), 2014-08
AKS 4100/
AKS 4100U
EKE 347
ICM with
ICAD motor
AKS 4100/
AKS 4100U
EKE 347
DKRCI.PI.RP0.C1.02 / 520H8794
70
2
Danfoss
80G76_06-2014
3b
EKE 347
Type = AKV / AKVA
3d
5
60
63
AKS 4100/
AKS 4100U
EKE 347
AKS 4100/
AKS 4100U
1

Advertisement

loading
Need help?

Need help?

Do you have a question about the EKE 347 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Danfoss EKE 347

  • Page 1 AKS 4100U AKS 4100U EKE 347 EKE 347 ICM with ICAD motor Danfoss Danfoss 80G76_06-2014 80G75_06-2014 AKS 4100/ AKS 4100U AKS 4100/ EKE 347 AKS 4100U EKE 347 Type = AKV / AKVA © Danfoss A/S (RC-MDP/MWA), 2014-08 DKRCI.PI.RP0.C1.02 / 520H8794...
  • Page 2 (pre 2010) plug for yellow green remote display 24 V DC gray brown CANbus connection ModBUS to other EKE controllers ICAD 2 gen (2010 +) orange brown 24 V DC yellow white DKRCI.PI.RP0.C1.02 / 520H8794 © Danfoss A/S (AC-MCI/MWA), 2014-08...
  • Page 3 Normally Open or Normally Closed Normally Closed AKV/AKVA POWER SUPPLY – Low Level Alarm 24 V AC 24 V DC Normally Open or Normally Closed +/- 20% 15 VA +/- 20% 10 W © Danfoss A/S (RC-MDP/MWA), 2014-08 DKRCI.PI.RP0.C1.02 / 520H8794...
  • Page 4: Connection Examples

    Connection examples EKE 347 - ON/OFF Application. Open/Close solenoid valve with coil 24V - 230V AKS 41/ AKS 4100/ AKS 41U AKS 4100U Voltage: 24 - 230 V a.c. AKS 4100/ AKS 4100/ AKS 4100U AKS 4100U POWER SUPPLY MASTER / SLAVE configuration...
  • Page 5 Setpoint Reference Active alarms Alarm setup Control Detailed status Controller info Display IO config. QR code Communication Service Setup wizard IO check Controller name Slider indicating position within the number of submenues © Danfoss A/S (RC-MDP/MWA), 2014-08 DKRCI.PI.RP0.C1.02 / 520H8794...
  • Page 6 15 and 16. 23-24 Expansion valve type: ICM with ICAD 13-14 Switch function for start/stop of controller. If a switch is not connected, terminals 13 and 14 must be shortcircuited. DKRCI.PI.RP0.C1.02 / 520H8794 © Danfoss A/S (RC-MDP/MWA), 2014-08...
  • Page 7 PV (Product version) only a few changes. Default password is Site (Production site) 100. QR code Code Below table shows authority given to the 3 levels. Read & Write Read only © Danfoss A/S (RC-MDP/MWA), 2014-08 DKRCI.PI.RP0.C1.02 / 520H8794...
  • Page 8 R = Read only N/A = Not shown (L) = Locked by Mainswitch ( Switch OFF Mainswitch for change of setting) (D) = Parameter is hidden if not active in the selected application DKRCI.PI.RP0.C1.02 / 520H8794 © Danfoss A/S (RC-MDP/MWA), 2014-08...
  • Page 9 R = Read only N/A = Not shown (L) = Locked by Mainswitch ( Switch OFF Mainswitch for change of setting) (D) = Parameter is hidden if not active in the selected application © Danfoss A/S (RC-MDP/MWA), 2014-08 DKRCI.PI.RP0.C1.02 / 520H8794...
  • Page 10 Press to return to last menu (EKE 347 as In/Out module) Once data entry has been confirmed, the Slave (EKE 347 as slave for another Master controller has sufficient data to do a qualified regulation of your system. 4. Regulating principle...
  • Page 11 © Danfoss A/S (RC-MDP/MWA), 2014-08 DKRCI.PI.RP0.C1.02 / 520H8794...
  • Page 12 DKRCI.PI.RP0.C1.02 / 520H8794 © Danfoss A/S (RC-MDP/MWA), 2014-08...